Village of 4 eco friendly rental houses
New Construction
- Building Type : Hotel, boarding house
- Construction Year : 2010
- Delivery year : 2013
- Address 1 - street : Fraissinet 15100 SAINT FLOUR, France
- Climate zone : [Cfb] Marine Mild Winter, warm summer, no dry season.
- Net Floor Area : 210 m2
- Construction/refurbishment cost : 354 166 €
- Cost/m2 : 1686.5 €/m2
-
Primary energy need :
138 kWhep/m2.an
(Calculation method : RT 2005 )
4 Rural biobased Bioclimatic at 1000m altitude, accessible, with successful applications of renewable energy (photovoltaics, solar water heaters, geothermal heating floors, Well "Auvergne").
Recovery of rainwater for toilets and washing machine, water source to 20m, light bulbs, electric hook for vehicles of the same name, solar pool shower ...
Sustainable development approach of the project owner
Photovoltaic, Geothermal, Solar Water Heater, Rainwater, Spring Water, Light Bulbs Low Conso, Wells Canadian Tri-selective, Compost, Recycling glass bottles reuse, Etc ...The pool is covered by a transparent shelter that allows a heating supplement - month of the year from 23 to 32 ° . In wintern geothermal heating to 20 ° to 24 °.
Architectural description
4 Chalets made of wood / spruce.Bioclimatic, Floors Geothermal heating by vertical 2 X 100m, Wall Insulation and Air 20cm foam under roof tiles Omega10 ...
No air conditioning: altitude 1000m
Building users opinion
See assessments on the ad type into Google: "660876 ABRITEL" heading assessments and also says "ABRITEL 868572"
A tourist told me one day in 2011: "Sir with your exemplary achievement you should be recognized of public utility."
If you had to do it again?
Choose by tenders more skilled craftsmen while limiting their number (+ plumber + electrician + heating renewables)
Look for examples of local authorities (unfortunately. .. Examples are scarce ...)
Energy consumption
- 138,00 kWhep/m2.an
- 187,00 kWhep/m2.an
Real final energy consumption
85,00 kWhef/m2.an
Envelope performance
More information
Only the result counts ....DPE Estimate in February 2009 = 197 kw / m2 D85 kW/m2 reality in 2012 =========== Class B
Water management
- 90,00 m3
- 150,00 m3
- 60,00 m3
Indoor Air quality
Reasons for participating in the competition(s)
1 chalet éco-construit en bois, orienté plein SUD pour Toit PHOTOVOLTAÏQUE Revendu à EDF0,50€ Kw x 4,4Kw Crete- Financierement = 3000€/an SUR 4000€ de consommation soit 75% financierement et40% en autoproduction
- 1 chaletde 13 couchages Avec ECSolaire de 400l
- Géothermie pour les 4 planchers chauffants + chauffage eau de piscine
- 2 puitscanadiens pour chauffage espace piscine + local technique
- Récupération eau de pluie pour WC et lave Linge
- Eau de sourceen sous sol (pompage par pompe électrique)
Building candidate in the category

Renewable energies
Other case studies

Institute of Botany of ULiège (Building B22) - Copy
- 31/01/2023
- /
- User User
- /
- 14

Pavillon de sanitaires du Chiro d'Itterbeek (Dilbeek) - Copy
- 31/01/2023
- /
- User User
- /
- 10

Vortex (Switzerland)
- 16/01/2023
- /
- Yasmina Sandoz
- /
- 308

TherapieStützpunkt
- 07/04/2021
- /
- Sabrina Gassner
- /
- 7513

House Solaris 416
- 02/04/2021
- /
- Michaela Fink
- /
- 4921

Charter Telecom headquarters
- 02/04/2021
- /
- Sarah King
- /
- 6487