GREENTER

8265
Last modified by the author on 08/02/2013 - 11:13
  • Building Type : Other commercial buildings
  • Construction Year : 2012
  • Delivery year : 2012
  • Address 1 - street : 56, rue des Ormes 37530 NAZELLES-NéGRON, France
  • Climate zone : [Cfb] Marine Mild Winter, warm summer, no dry season.

  • Net Floor Area : 1 100 m2
  • Construction/refurbishment cost : 850 000 €
  • Number of Visitor : 10 Visitor
  • Cost/m2 : 772.73 €/m2

Proposed by :

Certifications :

  • Primary energy need
    21.8 kWhep/m2.an
    (Calculation method : RT 2012 )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

This building office and storage uses only wood structure 110m3. Its format is similar to a gymnasium, its thermal performance allows it to be Minergie labelled. With its simple skeleton, we can easily imagine transform it into an office or dwellings.

Its flat roof without bitumen or PVC allows rainwater recovered without polluting. Its implementation, structure, insulation, finishing are made only from materials ecological wood, hemp, cellulose wadding earth .... or only solutions with low impact and easy to recycle envionmental.

This type of building high-performance, requires very little energy for its operation, thus avoiding oversized electrical infrastructure.

Tenants live in an environment without air pollutants (with natural materials), or electromagnetic, all solutions being shielded wire.

Sustainable development approach of the project owner

This ambitious project has been designed so that it is easily reproducible. The aim was to show that it is feasible to achieve a high performance building (Minergie) validated by a third party using only environmentally friendly materials, framing and insulation vegetable and natural finishes, plaster, clay, paint .... Efficient solutions lighting (LED only) or hot water (solar) can have a ridiculous consumption of electricity. Obviously, the heating is wood. Air tightness of n50 = 0454

Architectural description

The project is parallel to the Loire, since it is an obligation. Office offered the part south allows solar gain have important choice of finishes on these parts gives pride to the local woods, Douglas fir and chestnut.

See more details about this project

 http://www.envirobatcentre.com/upload/document/fiches_batiment/03_a2me/FILE_50864b89af342_greenter_a2me_fiche_detail.pdf/greenter_a2me_fiche_detail.pdf

Stakeholders

    Construction Manager

    DELBARRE-CAUX

    0247236440




    Contractor

    SCI Amaloire

Energy consumption

  • 21,80 kWhep/m2.an
  • 120,00 kWhep/m2.an
  • RT 2012

Envelope performance

    Slab insulation floating technopor R = 4, then 380 tonnes of inertia, thermal slab negative insulated 200mm cork, R = 5. Walls hemp wool insulation 200mm + 60mm + fermacell R = 6.8, roof insulation wadding 260mm R = 6.65.
    Office part substantially equivalent concrete slab of clay instead of cement.

  • 0,42
  • n50

  • 0,45

Systems

    • Wood boiler
    • Solar Thermal
    • No cooling system
    • Double flow heat exchanger
    • Solar Thermal
    • Wood boiler

Urban environment

  • 4 500,00 m2
  • 30,00 %
  • Building with natural and red wood sidingin the middle of an industrial area sadly white and metallic.

Product


    Wood fiber

    Steico/homatherm

     http://www.steico.fr

    Finishing work / Partitions, insulation

    Semi-rigid board insulation, rigid and loose


    Fermacell

    Xella

     http://www.fermacell.fr

    Finishing work / Partitions, insulation

    Gypsum interior and floor plates, 1500m2

    Stramentech

    Finishing work / Partitions, insulation

    Compressed straw panels to walls


    Auro

    Auro

     http://www.auro.fr

    Finishing work / paints, mural, wallcoverings

    Finishing paint, wood protection, paints and coatings.


    Argilus

    argilus

     http://www.argilus.fr

    Finishing work / flooring

    Coated earth, mud brick, concrete, clay



Construction and exploitation costs

  • 18 000,00

Energy bill

  • 1 600,00

Indoor Air quality

    materials without A+ nor VOC, F7 and G4 filter on VMC Double Flux

GHG emissions

  • 0,48 KgCO2/m2/an
  • calculation based on theoretical consumption of electricity and wood. (1 kWh electricity Ef = 0086 kg CO2 eq and wood 1KWh Ef = 0.013 kgeqCO2)

  • 60,00 année(s)
  • see methodology

Life Cycle Analysis

    -110

PDF

Share :
Author of the page

Nicolas DELBARRE-CAUX


Other case studies

More

Contest