The Link 345 Ciputra
- by EDGE Buildings
- /
- 2019-06-16 20:39:37
- /
- International
- /
- 4149 / EN
New Construction
- Building Type : Collective housing > 50m
- Construction Year : 2012
- Delivery year : 2018
- Address 1 - street : Khu ?ô th? Ciputra 100000 ?ôNG NG?C, B?C T? LIêM, HANOI, Other countries
- Climate zone : [Cwa] Mild, dry winter, hot and wet summer.
- Net Floor Area : 58 654 m2
- Construction/refurbishment cost : 79 800 €
- Number of Dwelling : 594 Dwelling
- Cost/m2 : 1.36 €/m2
-
Primary energy need :
kWhpe/m2.year
(Calculation method : )
Developed by Ciputra Westlake City Development Co. Ltd., The Link 345 Ciputra consists of three modern, 21-story residential complexes of nearly 600 two and three-bedroom units located in Hanoi. The residential towers offer a balanced combination of contemporary architectural style and energy-conscious design in order to improve the quality of life for its residents while reducing environmental impacts.
Residents enjoy a favorable location close to commercial centers and the diplomatic precinct northwest of Hanoi on the West Lake, with easy access to Noi Bai International Airport. Homeowners benefit from lower utility bills as smaller windows with shading, reflective paint and insulation help to keep the units cool without the need for air conditioning. The project is a result of a joint venture between Vietnam’s Urban Development and Infrastructure Investment Corporation and Indonesia’s Ciputra Group.
The Link 345 Ciputra has received final EDGE certification from SGS Vietnam.
See more details about this project
https://www.edgebuildings.com/projects/ciputra/Photo credit
Courtesy of Ciputra
Construction Manager
Stakeholders
Construction Manager
UDIC Hanoi
The Link is developed by Ciputra Group (Indonesia) and UDIC Hanoi
Energy consumption
- 55,00 kWhpe/m2.year
Envelope performance
More information
The study is about the building: Ciputra 3 Bedrooms_2.0.9
Real final energy consumption
49,80 kWhfe/m2.year
Product
Reduced Window to Wall Ratio - WWR of 22.14%
Reflective Paint for External Walls -Solar Reflectivity (albedo) of 80
External Shading Devices - Annual Average Shading Factor (AASF) of 0.33
Energy-Saving Light Bulbs - Common Areas and External Spaces
Second œuvre / Plomberie, sanitaire
Low-Flow Showerheads - 5.73 L/min
Low-Flow Faucets for Washbasins - 4.35 L/min
Dual Flush for Water Closets - 2.6 L/first flush and 4 L/second flush
Second œuvre / Cloisons, isolation
Insulation of Roof - U Value of 0.07
Insulation of External Walls - U Value of 2.03
Internal Walls: Medium Weight Hollow Concrete Blocks
Roof Insulation: Polystyrene
Water management
- 20 347,00 m3
Comfort
Reasons for participating in the competition(s)
Energy (21% energy savings) : Reduced window to wall ratio, reflective paint for external walls, external shading devices, insulation of roof and external walls; and energy-saving lighting for external spaces.Water (22 % water savings) : Low-flow showerheads and faucets and dual flush water closets.
Materials (24 % less embodied energy in materials) : Controlled use of concrete for roof construction and medium weight hollow concrete blocks for internal walls.
Building candidate in the category

Energy & Hot Climates

Low Carbon

Health & Comfort

Users' Choice
Author of the page
Other case studies

City Residential El Riyadh - Oran
- 19/11/2016
- /
- Omar MEZOUAR
- /
- 33402

Koranic El Djabiria Tafilelt Tajdit
- 03/07/2016
- /
- Ferial BOUNOUIOUA
- /
- 1214

Rural house - CNERIB
- 19/05/2016
- /
- Vincent Gilfaut
- /
- 14933

House Type Ksar Tafillelt
- 15/05/2016
- /
- abderrahmane zidane
- /
- 20907