Refurbishment project of an Alqueria , in order to get negligible HVAC energy demand.
- by Martínez Ana
- /
- 2017-06-08 16:03:10
- /
- International
- /
- 4559 / EN
Extension + refurbishment
-
Primary energy need :
14.38 kWhpe/m2.year
(Calculation method : Other )
The objective of this project was defined considering the current worldwide energy and environmental situation and the risen cultural interest for the traditional edifications.
With that purpose, an energy model was developed using energy software TRNsys 17 following these consecutive steps:
· First the necessary data sets such as climatic data and construction building characteristics were collected and studied.
· Then, an original housing energy model was performed in order to get a validation of the model (RMSE 1.63°C, MAPE 5.88%).
· After that, an energy optimization strategy was proposed. The following step was implementation of energy efficiency measures.
· Finally, the corresponding results were carefully analyzed.
The overall conclusions obtained from the analysis were:
a) A good matching of the energy model is fundamental in order to reproduce the specific thermal behavior of the studied building
b) Enhancing the building envelope is the most effective proposal to achieve the reduction in the HVAC requirements of the building.
Finally with the application of passive measures (measures applied to the building which do not require additional energy) was gotten zero energy demand of active air conditioning (Heating Demand: 0.7kWh/year m2, Cooling Demand: 2.2 kWh/ year m2).
A Blower Door test was carried out for the purpose of verifies if the tightness level is the appropriate according to the Passivhaus standard. The result was 1.49 renovations per hour, satisfying the tightness demand for building rehabilitation according the Passivhaus standard.
Presently, the project is in the phase of the construction process, remaining to be done some finished and the fitting of shadowing devices. Any active HVAC system and heating recovery haven’t been implemented.Pretending supply the HVAC requirements with natural ventilation in summer and with passive solar heating.
Coming, temperature and humidity sensors will be placed into of the house in order to prove if the house really has a nearly zero energy HVAC demand.
Data reliability
Self-declared
Stakeholders
Designer
Ana Martínez Developing energy model by means of energy software TRNsys 17. Energy analysis through simulation in order to chose the most effectiveness energy efficiency measures.Construction company
Salmer restauracion y conservacion, S.L.Owner approach of sustainability
Refurbishment of interest cultural house, how is the Alquería, trying to keep its characteristics and by means of implementing passive energy measures, achieve a nearly zero HVAC energy demand.
Architectural description
The house is a single isolated dwelling and consists of two floors, built in the first half of the XX century in the stage prior to the II Spanish Republic (1930). The house is located in a Valencian orchard, 820 meters from the Mediterranean coast, in the municipality of Alboraia (Valencia). The architectural typology is the modern alquería, a typical orchard farmhouse from the east and southeast coast of Spain and of Hispano-Muslim origin. Its main façade is orientated towards the east to take advantage of the breeze from the sea for ventilation and cooling of the farmhouse, especially during the summertime.
These types of buildings were houses of tillage in which the ground floor was used as a house, and the “cambra” or zone under the roof was for the storage of the harvest or for the breeding of silk worms. The geometry of the floors was typically rectangular, or as in our specific case, it could attach two rectangles forming a 90˚angle. The ground floor of the house is 60 m2 in area and 2.8 m. high.
Briefly, the constructive characteristics of the building are: solid brick masonry walls, without any thermal insulation. The floor and deck structure is made of wooden joists and beams. The pillars are solid brick. The south-facing shed roof is supported on the end gable of the roof east-west. The roofs are finishing with curved tiles.
Previously to the house’s refurbishment, an energy simulation study was carried out in order to achieve a negligible HVAC energy demand house. The analyzed measures for reduce the HVAC demand, were:
Passive energy efficiency measures:
The thermal insulation of the whole building enclosure.
Optimizing the windows area depending on the orientation.
Selection of the best characteristics for the windows.
Shading devices.
Free cooling obtained from cross ventilation.
Active energy efficiency measures:
Heating recovery.
Mechanical ventilation system.
Through the simulation was gotten the best option of each measure, being the HVAC requirements results of the developed simulation model with all of the proposed measures implemented close to 0.
Finally was decided not implementing heating recovery and mechanical ventilation systems in the building, only the passive measures will be implemented.
On the other hand in the refurbishment of the house has been tried to respect as much as possible the original appearance of the dwelling and the materials.
The structural consolidation of the building was needed. Due to its bad state, the deck was completely rebuilt, retaining its original typology, on its constructive elements. The intermediate floor was reinforced and was anchored to the walls. The walls in bad state were repaired following the original configuration.
Briefly, the changes regarding to the original house, have been the following:
Thermal insulation has been placed in all of the façades and the deck. In the walls has been disposed on the external face by means of SATE system.
In the south façade the original windows and doors has been replaced for four windows in order to get a properly passive heating by means of direct solar radiation.
For the purpose of avoiding overheating in windows facing to east, west and south orientation are going to be installed awnings.
The type of windows has been substituted for tilt PVC windows with LowE double glass.
The situation of the house enable good natural ventilation, therefore cooling requirements can be supplied by it.
Energy consumption
- 14,38 kWhpe/m2.year
- 54,52 kWhpe/m2.year
- 1,00 kWhpe/m2.year
Envelope performance
- 0,17 W.m-2.K-1
- 1,90
- 1,49
Systems
- No heating system
- Individual electric boiler
- No cooling system
- Natural ventilation
- Solar Thermal
Indoor Air quality
Health & Comfort
Product
-
External Thermal Insulation Composite System

Second œuvre / Cloisons, isolation
El Sistema SATE: Sistema de Aislamiento Térmico por el Exterior (en inglés ETICS: External Thermal Insulation Composite System), es un sistema EPS de aislamiento térmico y acústico de fachadas por el exterior. Mientras que otros aislantes se incorporan a la fachada mediante una obra, el Sistema SATE se trata de un panel de aislamiento prefabricado que se adhiere a las fachadas por fijación mixta (mediante fijación mecánica y adhesiva) por lo que dota a la fachada de una envolvente térmica que mejora la eficiencia energética y minimiza la fuga de calor y la entrada de humedad.
Como resultado de su composición de poliestireno expandido el sistema SATE es un panel aislante que proporciona aislamiento térmico en el exterior de la vivienda. Además cuenta con un revestimiento armado y al mortero acrílico.
Como resultado, el Sistema SATE (Sistema de Aislamiento Térmico por el Exterior) presenta estas ventajas:
Aislante térmico que disminuye la perdida de calor en invierno hasta un 70%.
Aislante térmico que reduce el calentamiento interno en verano hasta en un 30%.
Aislamiento acústico.
Resistencia al impacto solar.
Protege la fachada de la intemperie (larga durabilidad).
Garantiza la transpiración de la fachada.
Reduce el riesgo de condensaciones.
Instalación en el exterior de la fachada (no consume m² internos).
Bajo coste de mantenimiento (apenas necesita).
Impermeable.
Incombustible (A1)
100% Natural
Fácil y rápido de instalar
Permite gran variedad de acabados, incluso colores oscuros.
Por lo tanto, Aislamientos PIMAT considera que este Sistema SATE es un sistema de aislamiento térmico idóneo tanto para las nuevas construcciones como para rehabilitar fachadas exteriores deterioradas ya que otorga una mayor capacidad aislante térmica y acústica. Además, mejora la resistencia a agentes externos y apenas necesita mantenimiento.
This product was very appropriate because it was been able to install easily, and it present a very high resistance to heat transfer.
According with the climate of the zone using the appropriate measure in order to avoid a active HVAC system in other words getting a building with negligible energy HVAC demand.
The house is in refurbishment process yet.
Contest categories

Energy & Temperate Climates
Author of the page
Other case studies

SEMI OLYMPIC SWIMMING POOL COVERED IN SIDI YOUSSEF BEN ALI
- 25/03/2021
- /
- anass AMAZIRH
- /
- 5947

Environmental Education Center
- 20/06/2019
- /
- Saif Eddine Majdaoui
- /
- 4008

AttijariWafa Bank Drissia Business Center - Tangier
- 19/06/2019
- /
- Ibtissam GHAZZAR
- /
- 3566

House B autonomous
- 28/05/2019
- /
- Myriam Soussan
- /
- 10356

Masen center
- 06/12/2018
- /
- La rédaction C21
- /
- 2615

Kindergarten and elementary school AUDA ANFA
- 18/06/2018
- /
- Med El Azaar
- /
- 6603