Cooperative of 74 homes at Parque Ofimático

13086
Last modified by the author on 13/06/2017 - 14:59
  • Building Type : Collective housing < 50m
  • Construction Year : 2016
  • Delivery year : 2017
  • Address 1 - street : 15009 A CORUñA, España
  • Climate zone : [Csb] Coastal Mediterranean - Mild with cool, dry summer.

  • Net Floor Area : 13 633 m2
  • Construction/refurbishment cost : 6 105 160 €
  • Number of Dwelling : 74 Dwelling
  • Cost/m2 : 447.82 €/m2

Proposed by :

  • Primary energy need
    9.5 kWhpe/m2.year
    (Calculation method : )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building
​Residential building consisting of five basements of garage, ground floor for commercial premises, 9 floors dedicated to 74 houses and a floor under cover where the technical rooms of the building are located. Given the sustainable character that the Cooperative wants to give its building, they have decided to go several steps beyond the norm and obtain a GREEN Environmental Certification, which recognizes their criteria and guarantees their respect for the Environment, giving visibility to the good practices carried out finished. Among the main conditions to be respected, and totally unrenounceable, is the improvement of the quality of life of the users while maintaining the environmental values, all without increasing construction costs. This project involves the construction of homes with noble appearance, durable and functional finishes and high energy efficiency (with Energy Certification type A), and is about to become the first housing with GREEN Environmental Certification in the Galician Autonomous Community.

See more details about this project

 http://www.gbce.es/es/edificio/cooperativa-de-76-viviendas-libres-locales-y-garajes-en-el-parque-ofimatico

Data reliability

Assessor

Stakeholders



Contracting method

Other methods

Owner approach of sustainability

Residential building consisting of five basements of garage, ground floor for commercial premises, 9 floors dedicated to 74 homes and a floor under cover where the technical rooms of the building are located. Given the sustainable character that the Cooperative wants to give to its building, they have decided to go several steps beyond the norm and obtain a GREEN Environmental Certification, which recognizes its criteria and guarantees its respect for the Environment, giving visibility to the good practices carried out during the construction. Among the main conditions to be respected, and totally unavoidable, is the improvement of the quality of life of the users while maintaining the environmental values, all without increasing construction costs. This project involves the construction of homes with noble appearance, durable and functional finishes and high energy efficiency (with Energy Certification type A), and is about to become the first building of housing with GREEN Environmental Certification in the Galician Autonomous Community.

Architectural description

The Galician Cooperative Society of Parks Parque Ofimático aims to build a high quality building, durable and requiring low maintenance, with maximum energy efficiency and showing great respect for the environment. For this reason, it decided to go several steps beyond the norm and obtain a GREEN Environmental Certification, which is currently in process, and that it will recognize its criteria and guarantee its respect for the Environment, giving visibility to the good practices carried out. This project involves the construction of homes with a noble appearance, durable and functional finishes and a high energy efficiency (with Energy Certification type A), and is about to become the first building of housing with GREEN Environmental Certification in the Galician Autonomous Community .

Energy consumption

  • 9,50 kWhpe/m2.year
  • 89,20 kWhpe/m2.year
  • 3,60 kWhfe/m2.year
  • Heating: 2.10 kWhEP / m².year
    Cooling: 0.00 kWhEP / m².year
    ACS: 7.30 kWhEP / m².year

Envelope performance

  • 0,27 W.m-2.K-1
  • U covers: 0.33 W / m²K
    U facades: 0.27 W / m²K
    U exterior floors: 0.27 W / m²K
    U Glasses: 1.60 W / m²K
    Solar Factor Glasses: 0.59
    Air permeability of carpentry: Class 4

  • 0,34

Systems

    • Heat pump
    • Low temperature floor heating
    • Solar thermal
    • Heat pump
    • Solar Thermal
    • No cooling system
    • Single flow
    • Solar photovoltaic
    • Solar Thermal
    • Heat pump

    The architectural design is based on an environmental strategy based on the capitalization of the benefits of solar radiation and prevailing winds. On the resulting volume of building, an eave system is projected onto the façades

Smart Building

    All homes have a home automation system that allows both the management of alarms and the management of the operation of blinds, lighting and heating using tablet, pc or telephone with internet connection. They also have thermal counters

GHG emissions

  • 2,30 KgCO2/m2/year
  • Spanish Royal Decree: 47/2007

  • 50,00 year(s)

Life Cycle Analysis

    Indicators contemplated: Incorporated energy (57,363,474.82 MJ) and global warming potential - equivalent CO2 emissions (4,976.80).

Water management

  • 13 828,00 m3

  • The building has timed faucets of low flow and cisterns of double discharge to reduce the consumption of inner water as much as possible.

Comfort

    100% of the houses are protected of the exterior views. 50% of homes are entitled to the sun, so they get direct sunshine in the areas inhabited during the central hours of the day throughout the year. And 12% of the homes have private open spaces through terraces.

    Temperatura interior en invierno: 21°C - Valor de aceptabilidad: 90%

Product

    Ceramic sheet for ventilated facade LAMINAM

    LAMINAM

    [email protected]

     http://www.laminam.it/es/home/

    LAMINAM sintered porcelain sheet of 3000x1000 mm and 5 mm thickness for exterior sheet of ventilated facade system.

    Direct acceptance by recognition of the brand.



    Carpentry CORTIZO COR-60 blade hidden

    CORTIZO

    [email protected]

     https://www.cortizo.com

    Aluminum joinery CORTIZO COR-60 Blind sheet, European RPT channel. Classified class 4 according to UNE EN1026, 9A according to UNE EN102 and C5 according to UNE EN12211.

    Direct acceptance by recognition of the brand.


    Thermal insulation VERTIROCK DUO ROCKWOOL

    ROCKWOOL

    [email protected]

     http://www.rockwool.es

    Semi-rigid panel of uncoated 80 mm VENTIROCK DUO rock wool from ROCKWOOL for thermal insulation of facades.

    Direct acceptance by recognition of the brand.


    Heat pump SAMSUNG AM060FXMDGH / EU

    SAMSUNG

    [email protected]

     http://www.samsung.com/es

    SAMSUNG DVM S mini AM060FXMDGH / EU heat pump with 18 kW nominal power and COP of 4,10. Inverter Compressors with steam injection technology controlling the performance at low temperatures. Partialization from 5 to 100%.

    Direct acceptance by recognition of the brand.


    Radiator panel DIFUTEC of ALB

    ALB SISTEMAS

    [email protected]

     http://www.alb.es

    DIFUTEC® insulation panel, made of self-extinguishing expanded polystyrene (Eurocalse E) 30 mm thick and 30 Kg / m³ density. It has a superficial sheet of 0.25mm aluminum, heat diffuser, self-adhesive flaps and screen-printed guide grid.

    Direct acceptance by recognition of the brand.

Construction and exploitation costs

  • 634,13
  • 56 687,60
  • 6 105 161

Urban environment

The building is located in a new urbanization which represents the natural continuation of Matogrande, a fully consolidated urban area located at the entrance of the city of A Coruña. This urbanization constitutes a newly designed neighborhood with multitude of green areas. It is a perfectly connected area that has all the services and is surrounded by shopping centers.

Land plot area

1 000,00 m2

Built-up area

43,75 %

Green space

281,24

Parking spaces

The building has a total of five underground floors where the storage rooms and parking spaces are located. The total number of parking spaces is 128.

Building Environmental Quality

  • works (including waste management)
  • comfort (visual, olfactive, thermal)
  • water management
  • energy efficiency
  • renewable energies
  • integration in the land

Building candidate in the category

Energía & Climas Temperados

Energía & Climas Temperados

Bajo Carbono

Bajo Carbono

Salud & Comodidad

Salud & Comodidad

Edificio Inteligente

Edificio Inteligente

Premio de los Usuarios

Premio de los Usuarios

Green Solutions Awards 2017 - Edificios
PDF

Share :
Author of the page

María J. Maroño Breijo

Responsable de Certificaciones Ambientales LEED y VERDE


Other case studies

More

Contest

Green Solutions Awards 2017 - Edificios