Building EnergyPlus Orru

New Construction

  • Building Type : Isolated or semi-detached house
  • Construction Year : 2010
  • Delivery year : 2010
  • Address 1 - street : 39028 SILANDRO, Italia
  • Climate zone : [Dwa] Humid Continental Hot Summer, severe, dry winter

  • Net Floor Area : 170 m2
  • Construction/refurbishment cost : 310 000 €
  • Cost/m2 : 1823.53 €/m2

Certifications :

  • Primary energy need :
    5 kWhpe/m2.anno
    (Calculation method : )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

Passive House and Klimahaus Gold Plus, Passive House and CasaClima Oro Più, annual energy requirement of 3 kWh / m2a, 170m2 net, infrared electric heating system (1.5kW), 5.6kW photovoltaic system, solar thermal system, thermal coat 20cm rockwool, triple glazing fixtures.

See more details about this project

 http://old.tekneco.it/progetto/abitazione-energy-plus/

Data reliability

3rd part certified

 http://old.tekneco.it/progetto/abitazione-energy-plus/

Contractor

    Ing. Paolo Orru

    info@energyconsulting.eu

Construction Manager

    Ing. Paolo Orru

    info@energyconsulting.eu

Stakeholders

    Designer

    Ing. Paolo Orru

    info@energyconsulting.eu

Contracting method

Build and sell construction

Owner approach of sustainability

self-sufficient building with almost zero environmental impact

Architectural description

3-storey single-storey terraced building, sustainable materials on the outside and inside, free of thermal bridges. 1,5kW infrared electric heating system, photovoltaic system, thermal soles plant, controlled mechanical ventilation system with heat recovery, clay plaster

If you had to do it again?

Anything

Building users opinion

very comfortable, nothing management expense

Energy consumption

  • 5,00 kWhpe/m2.anno
  • 30,00 kWhpe/m2.anno

Envelope performance

  • 0,25 W/m2K
  • 0,43
  • 0,60
  • coat walls 20cm rockwool U 0.17
    roof 32cm wood fiber U 0.14
    Slab towards cellar 15cm perlite U 0.24

Real final energy consumption

    2 017

Systems

    • Electric heater
    • Individual electric boiler
    • No cooling system
    • Double flow heat exchanger
    • Solar photovoltaic
    • Solar Thermal
  • 100,00 %

GHG emissions

  • -9,00 KgCO2/m2/anno

Product

    Self-sufficient electric heating system

    Paolo Orru

    info@energyconsulting.eu

    Génie climatique, électricité / Chauffage, eau chaude

    Self-sufficient residential building

    Excellent comfort, zero operating costs

Construction and exploitation costs

  • 310 000

Urban environment

Inserted in a complex of terraced buildings

Building Environmental Quality

  • indoor air quality and health
  • biodiversity
  • acoustics
  • comfort (visual, olfactive, thermal)
  • energy efficiency
  • renewable energies

Contest categories

Energia e Climi Temperati

Energia e Climi Temperati

Utenti Preferito

Utenti Preferito

Green Solutions Awards 2018 - Edifici


Author of the page

  • Paolo Orru

    Engineer


  • Other case studies

    More

    Contest

    Green Solutions Awards 2018 - Edifici