Indospace Industrial Park Vallam

8846
Last modified by the author on 03/07/2019 - 12:03

Renovation

  • Building Type : Factories
  • Construction Year : 2011
  • Delivery year : 2018
  • Address 1 - street : Vallam Village, Sriperumbudur Taluk,Kancheepuram District. 600000 CHENNAI, India
  • Climate zone : [Aw] Tropical Wet & Dry with dry winter.

  • Net Floor Area : 13 395 m2

Certifications :

  • Primary energy need
    kWhpe/m2.year
    (Calculation method : )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

Near major highways and easily accessible to Chennai, the IndoSpace Industrial Park Vallam is situated in an ideal location for the warehousing sector. The park consists of four buildings, one of which has received EDGE certification, and provides leasing space to logistics and manufacturing companies. Tenants of the EDGE-certified building operate in a resource-efficient environment, allowing them to reduce their utility bills and channel more funds into their businesses. These green features are expected to reduce the utility costs of the building by more than $4,000, allowing tenants to pay nearly half the amount it would cost to operate in a traditional warehouse.

A pioneer of modern industrial and logistics parks, IndoSpace has constructed over 30 parks across India since it was founded in 2007. Each park is leased as a shell building without any internal touches and then rented to customers who can customize their own space for the needs of their businesses. All the buildings within a park share common areas such as parking and outdoor space. With more than 80 companies renting their warehouses, IndoSpace caters to both national and international companies such as Amazon and IKEA. The company is committed to building industrial spaces that allow tenants to maximize profit with minimal harm to the environment. IndoSpace Industrial Park Vallam has received final EDGE certification from GBCI.

See more details about this project

 https://www.edgebuildings.com/projects/indospace-industrial-park-vallam/

Photo credit

Courtesy of Indospace Industrial Park

Contractor

Construction Manager

Energy consumption

    16 kWhfe/m2.year : Lighting 10 kWhfe/m2.year : Other

  • 44,00 kWhpe/m2.year

Envelope performance

    Roof U - Value: 2.09 W/m² K
    Wall U - Value: 2.12 W/m² K
    Glass U - Value: 5.75 W/m² K

More information

11 kWhfe/m2.year : Fan energy 31 kWhfe/m2.year : Cooling Energy Both not counted in final energy use by EDGE

Real final energy consumption

    26,61 kWhfe/m2.year

Systems

    • No heating system
    • No domestic hot water system
    • No cooling system
    • Natural ventilation
    • No renewable energy systems

Product

    Génie climatique, électricité / Eclairage

    Reduced window to wall ratio
    Skylight(s) to Provide Daylight to 50% of Top Floor Area

    Second œuvre / Plomberie, sanitaire 

    -Dual flush water closets
    -Water-Efficient Urinals in all Bathrooms - 0.6 L/flush
    -Aerators & Auto Shut-off Faucets in all Bathrooms - 2.29 L/min
    -Black Water Treatment and Recycling System

    -Controlled use of concrete for floor slabs
    -Aluminum window frames
    -Roof Construction: Steel (Zinc or Galvanised Iron) Sheets on Steel Rafters
    -External Walls: Precast Concrete Panels , Steel Profile Cladding
    -Flooring: Finished Concrete Floor

Construction and exploitation costs

    Base Case Utility Cost: 678,296.00 Rs/Month
    Utility Costs Reduction: 307,509.00 Rs/Month
    Incremental Cost: 5,253,395.19 Rs
    Payback in Years: 1.42 Yrs.

Life Cycle Analysis

    Usage of non-hazardous materials

Water management

  • 22 279,00 m3
  • 1 Lts/person/day : water faucets
    14 Lts/person/day : landscaping
    1 Lts/person/day : other

    Water Savings: 25102.32 m³/Year

GHG emissions

  • 19,60 KgCO2/m2/year
  • 33,18 KgCO2 /m2
  • CO2 Emissions from Electricity Generation : 754.13 g/kWh

Reasons for participating in the competition(s)

​Energy (25% energy savings) : Reduced window to wall ratio and a skylight that provides daylight to 50% of the top floor area.

Water (53% water savings): Dual flush water closets, water-efficient urinals, aerators and auto shut-off faucets and a black water treatment and recycling system.

Materials (64 % less embodied energy in materials): Controlled use of concrete for floor slabs, steel sheets on steel rafters for roof construction, precast concrete panels and steel profile cladding for external walls, finished concrete flooring and aluminum window frames.

Building candidate in the category

Energy & Hot Climates

Energy & Hot Climates

Users' Choice

Users' Choice

Green Solutions Awards 2019 - Buildings
PDF

Share :
Author of the page

EDGE Buildings


Other case studies

More

Contest