Maison Notre Dame du Mont
- by Sandra Aoun
- /
- 2015-06-30 13:33:47
- /
- Internazionale
- /
- 9205 / EN
Renovation
- Building Type : Hotel, boarding house
- Construction Year : 1991
- Delivery year : 2015
- Address 1 - street : 01 Fatka main street 1401 FATKA, BYBLOS, Libanon
- Climate zone : [BSh] Subtropical Dry Semiarid (Steppe)
- Net Floor Area : 4 300 m2
- Construction/refurbishment cost : 159 999 €
- Cost/m2 : 37.21 €/m2
-
Primary energy need :
258.69 kWhpe/m2.year
(Calculation method : Primary energy needs )
Maison Notre Dame du Mont in Fatqais one of the reference hostels in the area.
Maison Notre Dame du Mont premises consists of a two main parts:
§ A four stories nursing home comprising 61 rooms with individualbathrooms
§ A four stories hotel comprising 120 rooms with individual bathrooms,1 central kitchen, 1 laundry, and 1 reception area with dedicated toilets.
This facility is a convent which can accommodate up to 181 residents. Thenursing home is inhabited by 61 people all year long. Whereas for the occupancyof the hotel, we assume that on average, the hotel is inhabited by 90 people onaverage all year long. Throughout the period of occupancy, the facility iscontinuously operational, since it is considered as a domestic living space.
A central domestic hot water system is installed for the entireproject. It is consisting of 4 boilers (used also for heating) located in atechnical room in Hotel’s basement and the following hot water storage tanks:
1. One hot water storage tank having 1500L of capacity serving NursingHome, with circulating pump, located in the same technical room.
2. A hot water storage tank having 1500L of capacity for Hotel first andsecond floors, with circulating pump, located in the same technical room.
3. A hot water storage tank having 750L of capacity for Kitchen andLaundry, with circulating pump, located in the same technical room.
4. A hot water storage tank having 1500L of capacity for Hotel third andfourth floors, with circulating pump, located in the a technical room atHotel’s roof.
See more details about this project
http://www.saintefamille.org/Data reliability
Self-declared
Stakeholders
Company
DAWTEC address: Dawtec, Lemec center, Furn El Chebbak, Baabda - LEBANON Tel/fax - LEBANON:+961-1-288688 Mobile - LEBANON:+961-70-288688 Tel - GERMANY:+49-15229046069 Email: [email protected] Consultancy design and contracting for Renewable Energy solutionsContracting method
Maximum Guaranteed Price
https://www.construction21.org/data/sources/users/15194/management.docxOwner approach of sustainability
Ste Famille Convent represented by Soeur Felix Khoury nowadays trying to implement green practices in most of their convents, schools, and elderly houses, first in the aim of conserving natural resources, and second in the plan of reduction of cost for power generation and increasing asset value and profit.
The whole project was studied and approved by LCEC Lebanese Center for Energy Conservation (is a national organization affiliated to the Lebanese Ministry of Energy and Water) and financed through NEEREA financing mechanism supported by “Bank De Liban”. Kindly find attached the complete study submitted before execution.
Architectural description
Maison Notre Dame du Mont premises consists of a two main parts:
A four stories nursing home comprising 61 rooms with individual bathrooms
A four stories hotel comprising 120 rooms with individual bathrooms, 1 central
kitchen, 1 laundry, and 1 reception area with dedicated toilets.
This facility is a convent which can accommodate up to 181 residents. The nursing home is
inhabited by 61 people all year long. Whereas for the occupancy of the hotel, we assume that
on average, the hotel is inhabited by 90 people on average all year long. Throughout the
period of occupancy, the facility is continuously operational, since it is considered as a
domestic living space.
If you had to do it again?
We execute the same system
Energy consumption
- 258,69 kWhpe/m2.year
- 250,00 kWhpe/m2.year
- 258,69 kWhfe/m2.year
- 258 693,00 kWhpe/m2.year
Envelope performance
- 0,42 W.m-2.K-1
Real final energy consumption
256 019,00 kWhfe/m2.year
256 019,00 kWhfe/m2.year
2 015
Product
-
Solar Pergola
The Pergola Solar System is an innovative product offering an architectural solution to a mechanical system without affecting its performance.
This system transforms solar energy into thermal energy for use in various applications such as Pool Heating, Water Heating, Space Heating, Process Heat and Solar Air Conditioning while preserving an aesthetic image. The Pergola Solar System being the only solar system with absorbers installed at 0 degree of inclination and having a system structure that can be constructed from a wide variety of materials makes the Pergola Solar System a unique design for Solar Water Heaters.
The diversity of materials and colors present an added value to the system, as the structure could be made from wood, aluminum, colored steel, stainless steel… to suit different architectural needs.
The Pergola Solar System was patented in 2009 (Patent No. 8589 - Ministry of Economy and Trade – 2009). This keeps the Pergola Solar System away from the competition whirlpool.
The Pergola Solar System is a pioneering product outweighing all standard type solar systems available in the market. Its uniqueness increases its commercial value.
The Pergola solar system can be easily expanded or upgraded on demand
The Pergola Solar System is a pioneering product outweighing all standard type solar systems available in the market. Its uniqueness increases its commercial value.
Author of the page
Other case studies


DomusLignea
- 05/06/2018
- /
- vincenzo guzzo
- /
- 5794

Residence Visioneire
- 05/06/2018
- /
- vincenzo guzzo
- /
- 7224

REEF SANSONE - Bar Restaurant
- 28/03/2018
- /
- Massimiliano Pardi
- /
- 17807

CASA UD
- 13/03/2018
- /
- Monterisi Tiziana
- /
- 6296

Humanitas University Campus
- 06/06/2017
- /
- Filippo Taidelli Architetto
- /
- 12202