Avenger

10699
Last modified by the author on 25/09/2018 - 11:49

New Construction

  • Building Type : Isolated or semi-detached house
  • Construction Year : 2017
  • Delivery year : 2017
  • Address 1 - street : 23150 AHUN , France
  • Climate zone : [Cfb] Marine Mild Winter, warm summer, no dry season.

  • Net Floor Area : 252 m2
  • Construction/refurbishment cost : 373 000 €
  • Number of Dwelling : 1 Dwelling
  • Cost/m2 : 1480.16 €/m2

Certifications :

  • Primary energy need
    30 kWhep/m2.an
    (Calculation method : Other )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

After several years of R & D, Avenidor has embarked on an extraordinary project: to build the 1st Passive Premium certified and 100% autonomous house in the world.

The Avenidor building is located in the KZB Group's sustainable housing center (Ahun in Creuse).

Here are the peculiarities of this house:

  • Certified passive premium by the PassivHaus Institute

No heating or cooling system (thanks to the design of the envelope and the orientation of the building in order to make the most of the solar contributions)

  • Exceptional living comfort (no cold areas, optimal air quality, etc.)

100% autonomous in electricity (fields of photovoltaic panels bi-facial and park batteries)

100% autonomous in drinking water (rainwater drilling or recovery, filter body purification system and UV bactericide)

  • WIFI system without being connected to the traditional wired network (amplification of the 4g and redistribution in WIFI)

In short, this house is so powerful that it surpasses the RT2020 (future thermal regulation of the building), it works by making the most of what nature has to offer.

Our goal is to make this type of housing accessible to all and thus drastically reduce pollution related to buildings. That is why, from September 2018 we offer our solutions to individuals wishing to afford an exceptional house, tailor-made and eco-responsible.

Sustainable development approach of the project owner

Pollution related to the building activity sector accounts for 25% of total CO2 emissions in France.

Alarmed by this observation Avenidor aims to design houses that have no impact on the environment, from their realization to their use. In order to take up this major challenge, the prototype presented here has been developed to consume very few resources and use only renewable energies, while favoring materials with low environmental impact.

Architectural description

Architecturally inspired Alsatian, the house Avenidor is built of cellular concrete (masonry material the least impacting ecologically and offering the best performance) and is insulated with polystyrene (recycled) extruded under raft and expanded in elevation. This house of 252m ², has 3 levels:

  • A basement in heated envelope
  • Ground floor (living room and open kitchen, WC)
  • R + 1 (3 bedroom and 3 bathroom)

Through its aesthetics, Avenidor demonstrates that a high-performance building can have a traditional architecture. One of the challenges of this construction was to make half-timbering reconstituted stone fixed directly on the ITE without diminishing the effectiveness. In addition to benefit from a perfect insulation (R of 10 on average overall envelope) the building is oriented in order to make the most of the bioclimatic contribution (maximum opening to the south and very little to the north) .Here is precisely the constructive mode of the house:

Raders:

From bottom to top :

  • All coming 100mm
  • Geotextile membrane
  • DOW XPS (λ = 0.029 W / mK) 240mm
  • Anti-hiking membrane
  • Reinforced concrete slab (λ = 2,500 W / mK) 300mm

U Radices = 0.104W / (m²K)

Exterior walls:

From outside to inside walls:

  • 25 mm reconstituted stone cladding (aesthetic function)
  • Crepe facade covering 15 mm
  • TE ZOLPAN EPS (λ = 0.038 W / mK) 200mm
  • YTONG cellular concrete block (λ = 0.090 W / mK) 365mm
  • SIGA steam
  • Unvented air gap 48mm
  • 18mm plasterboard

    UMurs ext = 0.098W / (m²K)

Roofing:

From outside to inside:

  • Roof tiles
  • By rain
  • Fir farmhouse
  • Projected cellulose wadding (λ = 0.039 W / mK) 600mm
  • Oriented Strand Board 22mm
  • SIGA steam
  • Ceiling in plasterboard 13mm

UToiture = 0.073W / (m² / K)

Window

  • HF310 Wood-aluminum frame chassis
  • Triple glazing 48mm, 44b.2 (VSG) / 16Ar / 4 / 15Ar / b4

U g-value = 0.88 W / (m²K)

g -value = 60%

Uw = 0.898 W / (m²K)


Building users opinion

All the people having stayed in our house are unanimous on the comfort of life which it proposes:
Irreproachable quality of the air managed by the VMC double flux.
Outstanding acoustic comfort
Feeling of homogeneous heat throughout the house

If you had to do it again?

As our prototype house has achieved the expected consumption and performance targets, we would like to increase the share of bio-sourced in our homes. This is why we are currently developing a straw house carrier that will have the same performance and will also be 100% autonomous.

See more details about this project

 https://www.avenidor.com/

Contractor

Construction Manager

Stakeholders


    Thermal consultancy agency

    SRKLIM

    Legros Jean-Paul

     http://groupekzb.com/

    Thermal Study and Fluid Management Office

Contracting method

Lump-sum turnkey

Energy consumption

  • 30,00 kWhep/m2.an
  • 50,00 kWhep/m2.an
  • Other

    Hot water requirements: 11.03 kWh / m².an Heating requirements: 7.44 kWh / m².an Cooling requirements: 0.6 kWh / m².an Auxiliary electricity: 2.71 kWh / m².an Specific electricity: 6.14 kWh / m².an VMC double flow (need in electricity): 2.7 kWh / m².an

Real final energy consumption

    31,00 kWhef/m2.an

    31,00 kWhef/m2.an

    31,00 kWhef/m2.an

    2 018

Envelope performance

  • 0,10 W.m-2.K-1
  • Here is precisely the constructive mode of the house:
    Raders:
    From bottom to top :
    All coming 100mm
    Geotextile membraneDOW XPS (λ = 0.029 W / m.K) 240mm
    Anti-hiking membrane Reinforced concrete slab (λ = 2,500 W / m.K) 300mmU
    Raders = 0.104W / (m²K)
    Exterior walls:
    From the outside to the inside of the walls:
    25 mm reconstituted stone cladding (aesthetic function)
    Crepe facade covering 15 mmTE ZOLPAN EPS (λ = 0.038 W / m.K) 200mm
    YTONG cellular concrete block (λ = 0.090 W / m.K) 365mm
    Steam SIGAVide unventilated air 48mm
    Gypsum board 18mmU Walls ext = 0.098W / (m²K)
    Roofing:
    From the outside to the inside:
    TilesFor rainFarm fir treeUse of projected cellulose (λ = 0.039 W / m.K) 600mm
    Oriented Strand Board 22mm
    SIGA vapor barrier 13mmU plasterboard ceiling
    Roofing = 0.073W / (m² / K)
    Internally Window Wood-Aluminum HF310Triple Glazing 48mm, 44b.2 (VSG) / 16Ar / 4 / 15Ar / b4U g-value = 0.88 W / (m²K) g -value = 60% Uw = 0.898 W / (m²K)

  • 0,60
  • n50

  • 0,18
  • Extremely easy to use.

    Perfect.

More information

The house is 100% autonomous thanks to its field of 96 m² bifacial photovoltaic panels (sized for two buildings) and its battery park. Production of photovoltaic panels = 19.2 kW peak battery storage capacity 15 kW

Systems

    • Heat pump
    • Heat pump
    • No cooling system
    • Double flow heat exchanger
    • Solar photovoltaic
  • 100,00 %
  • The site is supplied with electricity by 96m² of photovoltaic panels bifacial (20% additional production) connected to an automated battery park. The bifacial panels are placed on a white slab and along a pond to enjoy a phenomenon of reverberation and donate more.The system generates electricity for 2 buildings (19.2 kW peak and 15kW storage), whose Avenidor house. Treatment and purification system for drilling water by filter body and UV bactericide. Microstation purification, operating without electricity, for the total treatment of gray and black water.

    Échangeurs thermiques pour la récupération de chaleur sur eau grises. VMC double flux avec rendement à l'échangeur de 90%

Smart Building

    Intelligent because of its simplicity. Intelligence is in the design of the building

    Automatically manage by the energy storage system.

    RAS

Urban environment

  • 24 000,00 m2
  • 112,00 %
  • 13 000,00
  • Building realized on the Research and Development Center of the KZB Group.

    In the middle of the woods. Bordering 2 lakes.

Product

    House Avenidor

    SETIM

    Arnaud Ramelot, DO, [email protected]

     http://www.groupekzb.com

    Table 'c21_italy.innov_category' doesn't exist SELECT one.innov_category AS current,two.innov_category AS parentFROM innov_category AS oneINNER JOIN innov_category AS two ON one.parent_id = two.idWHERE one.state=1AND one.id = '33'

    1st certified Passive Premium home and 100% autonomous. It is the combination of materials, equipment, know-how and studies that made this house a success. Nowadays we have the experience and the technology to build the future, why stay anchored in the past?

    Each stakeholder must be told the purpose and the issue of their work. On-site crews are rigorous when they understand the impact of their tasks on building performance. The most complicated is to obtain the insurance of CMiste (procedure started in November 2017 ...)

Construction and exploitation costs

  • 680 000,00
  • 3 500,00
  • 80 000,00
  • 75 000
  • 650 000

Water management

  • House totally off networks. Drilling water.

Indoor Air quality

    Optimal: about 350 ppm on average (house in Creuse, in the countryside)

Comfort

    Optimal.

    350

    de 350 à 1200ppm avec des fumeurs

    20 et 25

    de 19 à 24.6

    27dB on one of the ventilation vents (worst measurement)

GHG emissions

  • 0,45 KgCO2/m2/an
  • GES calculation tool developed by Ecobatiment

  • 1,00 KgCO2 /m2
  • 100,00 année(s)
  • 297,00 KgCO2 /m2
  • RAS

     RAS

Life Cycle Analysis

    89

  • 45,00 kWhEP
  • RAS 100% bio-sourced prototype under design. Start of work on July 30, 2018

Reasons for participating in the competition(s)

The Avenidor house is 100% autonomous and certified Passive House Premium.

In summary, this dwelling:

  • Is totally off-grid
  • Enjoy all the natural resources of its environment
  • Recycles the majority of its thermal energy (exhaust air exchanger & gray water)

A technical data collection system has been implemented in this prototype to study the behavior of the building over the long term.

The constructive system is as follows:

Raders:

From bottom to top :

  • All coming 100mm
  • Geotextile membrane
  • DOW XPS (λ = 0.029 W / mK) 240mm
  • Anti-hiking membrane
  • Reinforced concrete slab (λ = 2,500 W / mK) 300mm

U Radices = 0.104W / (m²K)

Exterior walls:

From the outside to the inside of the walls:

  • 25 mm reconstituted stone cladding (aesthetic function)
  • Crepe facade covering 15 mm
  • ITE ZOLPAN EPS (λ = 0.038 W / mK) 200mm
  • YTONG cellular concrete block (λ = 0.090 W / mK) 365mm
  • SIGA steam
  • Unvented air gap 48mm
  • 18mm plasterboard

U Walls ext = 0.098W / (m²K)

Roofing:

From the outside to the inside:

  • Roof tiles
  • By rain
  • Fir farmhouse
  • Projected cellulose wadding (λ = 0.039 W / mK) 600mm
  • Oriented Strand Board 22mm
  • SIGA steam
  • Ceiling in plasterboard 13mm

U Roof = 0.073W / (m² / K)

Window

  • HF310 Wood-aluminum frame chassis
  • Triple glazing 48mm, 44b.2 (VSG) / 16Ar / 4 / 15Ar / b4

U g-value = 0.88 W / (m²K)

g -value = 60%

Uw = 0.898 W / (m²K)

Double flux ventilation :

  • MAICO WS 470
  • Heat recovery system HER = 87.6%
  • Sheath insulation (λ = 0.039 W / mK) - 100mm
  • Heating coil (copper spiral) downstream of the VMC to heat the air to breathe VMC in winter

Domestic hot water :

  • Air / water heat pump DAIKIN Altherma BT 260L
  • Heat exchangers under the shower trays.

Ecological aspect:

96m² of two-sided photovoltaic panels (20% additional production) connected to an automated battery park. The system generates electricity for 2 buildings, including the Avenidor house.

ZOLPAN depolluting paints have been used to clean indoor air (up to 80% reduction in VOCs).

Drinking water treatment and purification system (filter body and UV bactericide).

Heat exchangers for heat recovery in greywater.

Microstation purification, operating without electricity, for the total treatment of gray and black water.

Data and consumptions:

  • Living area of ​​the house: 252m²
  • Air permeability N50 = 0.18 / h
  • Production of photovoltaic panels 19.2 kW peak
  • Need annual heating 6kWh / (m²a)
  • Primary energy requirement: 43 kWhEP / m² / a (on the heating system, domestic hot water, domestic electricity and auxiliary electricity).
  • Price of the house: 1489 € / m²

Building candidate in the category

Energie & Climats Tempérés

Energie & Climats Tempérés

Coup de Cœur des Internautes

Coup de Cœur des Internautes

Prix des Etudiants

Prix des Etudiants

Green Solutions Awards 2018 - Bâtiments
PDF

Share :
Author of the page

Bense Antoine

Directeur des opérations


Other case studies

More

Contest

Green Solutions Awards 2018 - Bâtiments