Rivière-Salée Medico-Social Center

  • Building Type : Other building
  • Construction Year : 2020
  • Delivery year : 2020
  • Address 1 - street : rue Lévesque 98000 NOUMEA, France
  • Climate zone : [Aw] Tropical Wet & Dry with dry winter.

  • Net Floor Area : 2 055 m2
  • Construction/refurbishment cost : 6 704 000 €
  • Number of none : 50 none
  • Cost/m2 : 3262.29 €/m2
  • Primary energy need
    84 kWhep/m2.an
    (Calculation method : Other )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

This building was awarded the Energy & Hot Climates Prize of the Green Solutions Awards 2020-21 at both national and international levels.

The Rivière-Salée medico-social center is located in Nouméa, New Caledonia. It is located in the Rivière-Salée district, in an urban area near other public facilities, in a hot and humid tropical climate.

It brings together medical care and consultation rooms, a radiology center, an analysis laboratory, offices, waiting areas and rest areas for the public or staff.

Its ambitious bioclimatic design is the result of a combined desire of the client to have an economical and resilient building, of the designers to offer an exemplary building for the Caledonian territory in all aspects of sustainable development, and of the users of benefit from healthy and comfortable premises for staff and the public.

Beyond the environmental and bioclimatic aspects, it is also a social and cultural approach that has been developed in the architecture and the landscape, with the objective of achieving an Oceanian building in which users recognize and find themselves.

Thus, the building revolves entirely around a large central patio heavily vegetated, thus making it possible to release rooms open to semi-outdoor spaces protected from the weather and the nuisances of the city. This patio is organized as a low pressure fireplace to accentuate air circulation and promote natural ventilation. The facades on the street are all provided with a double skin in porous mesh, a generalized solar filter also providing protection against urban degradation to which all buildings in the area are subject.

Thus, the majority of premises can operate with natural ventilation without air conditioning, opening onto a quiet and shaded haven , in the heart of the surrounding mineral and overheated town. The wide use of wood and the dry sector also contributes, beyond the search for a reduced carbon impact, to the appropriation of spaces and buildings by users.

 

Sustainable development approach of the project owner

Main objective of an economical, comfortable and healthy building.

The technical program included precise and high-performance environmental requirements, developed in a specific thesis on the environmental quality of the project, and including in particular numerous justifications to be presented by the team of designers during the studies (dynamic thermal simulations, calculations of solar factors , simulations, ...).

An environmental approach, sometimes simply addressed on previous projects, was developed by the MOA for the first time in a comprehensive manner on this project.

Architectural description

The Rivière-Salée medical-social center is a tropical Oceanian bioclimatic building.

All the premises are articulated around the central patio, the true heart of the project, both for its active role in natural ventilation and for its lush vegetation that adorns all the spaces.

The exterior facades are all covered with a protective double skin that filters solar gain, rain, dust, views and possible frequent degradation in the area.

With the exception of the technical rooms and the laboratory, all spaces are through or semi-exterior, to promote natural ventilation and limit the use of air conditioning.

Building users opinion

A detailed post-construction assessment is planned after 6 months of use (July 21). Detailed questionnaires will be completed by all staff on the concepts of thermal and visual comfort, the use of technical systems, etc.
The first feedback from occupants over the first 2 months of use shows great satisfaction in the use of the premises and their comfort.

If you had to do it again?

Since the start of use, in January 2021, some adjustments have been made: - problem of dazzling of people stationed at the reception of the R + 2, semi-outdoor space. Additional blinds have been installed to protect from direct sunlight. - the commissioning of the GTC system and the handling by the staff remains, 3 months after delivery, still hesitant. Technical system sophisticated but difficult to use without technical staff permanently in the establishment. Need for a specific procedure for securing the premises in the event of cyclones, in particular the semi-outdoor spaces and the furniture located in these spaces, which had to be adjusted and detailed to the staff after the first cyclone alert.

See more details about this project

Photo credit

Urban Ecology Laboratory

Contractor

Construction Manager

    Atelier d'architecture KASO

    claire PASCAL ; cp[a]atelierkaso.com

Stakeholders



    Other consultancy agency

    Laboratoire d'Ecologie Urbaine

    jocelyn MESCHENMOSER ; leu[a]nautile.nc

     https://www.leureunion.fr/

    Environmental Quality Study Office


    Other consultancy agency

    ECEP

    +687 23 22 22

    design office for all trades


    Environmental consultancy

    LFJ design paysage

    Laetitia Franzini Jacquin

    landscaper


    Other consultancy agency

    SIGMA

    Joel Beaumont

    BET VRD


    Other consultancy agency

    ES2

    Anne Gesdon

    BET fire safety

Type of market

Global performance contract

Energy consumption

  • 84,00 kWhep/m2.an
  • 225,00 kWhep/m2.an
  • Other

    air conditioning and treatment: 32580 kWh / an EF VMC: 2895 kWh / an EF air conditioners: 1430 kWh / an EF lighting: 13125 kWh / an EF sensor: 6000 kWh / an EFE for sanitary heating: 1800 kWh / an EFTOTAL: 57 830 kWh / an EF

Real final energy consumption

    33,00 kWhef/m2.an

Envelope performance

    solar factors: metal roof: 0.015
    insulated roof terrace: 0.018
    facades NE, NO, SW: 0.007
    SE facade: 0.005
    Jealousy berries NE: 0.30
    fixed bays NE: 0.27
    OSB or sliding windows NE: 0.27
    jealousy berries NO: 0.33
    fixed bays NO: 0.29
    OSB bays NO: 0.30
    Jealousy berries SO: 0.35
    Fixed bays SO: 0.31
    OSB SO bays: 0.32
    Jealousy berries SE: 0.23
    Fixed bays SE: 0.20
    OSB SE racks: 0.21

    GTC difficult to learn for non-technical staff. During the studies, it was expected that a technical staff would be in the future building to ensure its operation. This is no longer the case, this staff being relocated. The use of the GTC by administrative staff remains difficult.

More information

A mission to monitor actual consumption during the first year is planned by the environmental consultant. It will make it possible to identify certain drifts and to take stock at the end of the first year of use. Signs specifically designated for this building were also produced, to make users aware of energy savings and the proper use of technical devices and systems.

Systems

    • No heating system
    • Solar Thermal
    • VRV Syst. (Variable refrigerant Volume)
    • Natural ventilation
    • Free-cooling
    • Single flow
    • Solar photovoltaic
  • 51,00 %
  • Photovoltaic rooftop farm of 35kWp, operating in self-consumption with surplus resale.

Urban environment

  • 2 965,00 m2
  • 47,00 %
  • 757,00
  • The surrounding environment consists of public or service buildings in an urban development of medium density. The immediate neighborhood consists of a vocational school, a sports stadium, a public service pole building, a public parking lot, a shopping center, a cultural center, a church.

    The Rivière-Salée district, an old but relatively isolated district, has benefited for several years from urban renovation or requalification, driven by the arrival of the TCSP (neobus), an important stop of which is located 50m from the medico-social center.

Product

    RESYSTA

    Resysta

     https://www.resysta.com/

    Gros œuvre / Structure, maçonnerie, façade

    Realization of all the double-skin slats in RESYSTA material. After a long comparative analysis of different materials and solutions, it was decided to produce these elements with this composite consisting of rice husk, rock salt of mineral oil. It was chosen for its mechanical properties, its resistance to degradation and bad weather, but above all its very efficient environmental performance. In all, 8770 boards 70cm long were used on the 3 most exposed facades. This material, which is highly visible on the building, helps to highlight the project owner's environmental commitment to this project.

    Implementation, handling and work as easy as wood according to the structural company responsible for the installation.

Construction and exploitation costs

  • 830 000
  • 7 534 000

Water management

  • 400,00 m3
  • 40,00 m3
  • Rainwater collection on the roof over 400m², storage in an underground tank of 5000 liters, distribution for the supply of irrigation networks to all the green spaces outside (patio) and planters upstairs. All irrigation needs can be covered by recycled rainwater, the plant systems implemented being able to withstand a period of drought if necessary.

Indoor Air quality

    The interior coverings (flexible floors, paints, varnishes, glues) have all been selected for their environmental characteristics and their low levels of VOC emissions (environmental labels or FDES sheets required, etc.).

Comfort

    As it relates to a medico-social establishment, several provisions have been developed for comfort and health:

    - thermal comfort, with bioclimatic design and privileged natural ventilation (dimensioning by studies in a wind tunnel and dynamic thermal simulations)

    - visual comfort, with favored natural lighting, while completely avoiding glare phenomena (sizing by digital simulations).

    - All waiting, reception and circulation areas are treated as open outdoor spaces but protected from rain, sunshine and strong winds.

    - All offices and medical practices are equipped with ventilators, desk lamps, and blinds with individual controls so that each user can adapt the operation of the systems to their needs and feelings.

    - the ubiquitous vegetation in the building, including upstairs, promotes a peaceful and intimate atmosphere suitable for a care activity

    Simulations thermiques dynamiques avec DesignBuilder (moteur de calcul Energy+). Les taux de confort (pourcentages de points dans le diagramme de givoni) sont compris entre 92 et 94% pour tous les lcoaux type simulés

    campagne de mesure hygrothermique dans 5 locaux type prévue en avril 2021, à l'aide d'enregistreurs de température et hygrométrie Testo 174H2

    For the sake of acoustic comfort for users and employees, different
    provisions have been put in place:
    - Acoustic aluminum ceilings for waiting-reception areas
    - Acoustic ceilings in mineral fibers for offices and medical practices
    - Acoustic ceilings in plasterboard for meeting rooms and cafeterias
    - Isophonic screeds for circulation
    - Soft floors in a majority of premises
    The objective is to limit the reverberation within the spaces, as well as the transmission
    impact noises between floors
    Between rooms, the dividing walls are made of high hardness plasterboards
    on frame with incorporated mineral wool. The sound reduction index of these
    walls is Rw + C (Ra) = 47 dB.
    The technical terrace roof air treatment equipment will be located on
    anti-vibration mounts and are located at a distance greater than 40m from the nearest
    neighboring construction which will greatly limit noise pollution
    possible on neighboring establishments.

    FLJ moyen dans les locaux simulés (outil DIAL+): à noter, le climat tropical impose de respecter des FLJ plus faible qu'en climat européen pour obtenir les mêmes conditions de confort visuel dans les locaux. Bureau médecin façade SE au R+2: FLJmoyen = 2

GHG emissions

  • 30,00 KgCO2/m2/an
  • Scope: electricity consumption excluding photovoltaic resale, air conditioning leaks, patient travel, personal travel. Electricity consumptions are those calculated in a study according to the RENC method (FE 0.920 kgCo2 / kWh elec EF).

  • 50,00 année(s)

Reasons for participating in the competition(s)

The building allows operation in natural ventilation and therefore economical, thanks to the articulation of the premises around a low pressure patio whose dimensions have been determined by studies on a model in a wind tunnel.

Integration of vegetation in the heart of the building to contribute to natural refreshment: in the lush patio, vegetated terraces, very large hanging planters on the upper floor, vegetated front feet, green parking.

Main framework in reinforced concrete, but very extensive use of the dry process and wood for the filling of the facades (steel and firbocement), the double-skin and cladding of the facades (exotic wood, Resysta), the main staircase (steel, wood), various furniture and cladding (wood).

Global approach to energy control, with a limitation of the air-conditioned area, operation with natural ventilation for most spaces, economical equipment (regulated and optimized VRV air treatment, DC motors, LED lighting, stirrers efficient air, ...), solar hot water production, and a photovoltaic solar farm on the roof operating in self-consumption connected to the network.

Health and care building with an approach centered on the comfort of patients and staff: thermal comfort in the hot season with optimized natural ventilation and a naturally cooled building, visual comfort with natural lighting favored in all premises by a double exposure and large windows all protected from direct sunlight, olfactory comfort with a building facing the protected patio and the presence of vegetation in all spaces even upstairs, acoustic comfort with wood mesh coverings for the patio and the waiting areas. the materials and coatings are chosen for their environmental characteristics and their low levels of VOC emissions.

PDF
 tropical bioclimatism natural ventilation wood health and comfort caledonia oceania revegetation photovoltaics

Share :
Author of the page

jocelyn meschenmoser

directeur