Air Lorraine (head office)
New Construction
- Building Type : Office building < 28m
- Construction Year : 2009
- Delivery year : 2009
- Address 1 - street : 20 allée de Longchamp 54600 VILLERS-LES-NANCY, France
- Climate zone : [Cfb] Marine Mild Winter, warm summer, no dry season.
- Net Floor Area : 416 m2
- Construction/refurbishment cost : 1 205 000 €
- Number of Work station : 20 Work station
- Cost/m2 : 2896.63 €/m2
-
Primary energy need
70 kWhep/m2.an
(Calculation method : RT 2005 )
Air Lorraine is an approved association monitoring air quality in Lorraine. The objectives of this project were to build a new headquarters for best performance, a combination of different poles and a better reception for the public while engaging in a process of ustainable development based on transferable constructive solutions based on the desire to raise awareness and educate potential visitors to meet current environmental challenges. The building includes offices, meeting rooms and laboratories on one level.
Sustainable development approach of the project owner
Project Objectives: To reach the BBC level (winner of PREBAT (Programme for Research in Low energy Buildings) and follow a comprehensive approach to environmental quality. Originality: mud brick interior wall, measuring the quality of indoor air, circular building, glass double-skin, cellulose wadding and wood cap / water, photovoltaic, rainwater recycling, natural lighting sheds, low emissive VOC indoor furniture.Architectural description
Circular structure snail shape.Building users opinion
More info via the link
If you had to do it again?
More info via the link
See more details about this project
http://www.lqe.fr/home/upload/fiches/FicheAirLorraineVillersDesREX.pdfStakeholders
Contractor
Air Lorraine
SCHMITT Jean-Pierre
http://www.atmolor.orgAssistance to the Contracting Authority
Solorem (Nancy)
Designer
Klein & Baumann Architectes (Mulhouse)
Construction Manager
Kelin & Baumann Architectes (Mulhouse)
Assistance to the Contracting Authority
Cap Terre (AMO qualité environnementale)
Other consultancy agency
Barthes (structure - 54)
Thermal consultancy agency
Solares Bauen (+ fluides - Strasbourg)
Other consultancy agency
Economie E3 (économie de la construction - Strasbourg)
Energy consumption
- 70,00 kWhep/m2.an
- 145,00 kWhep/m2.an
More information
More info via the link
Systems
- Geothermal heat pump
- Double flow heat exchanger
- Heat pump (geothermal)
Product
Mud brick

Second œuvre / Cloisons, isolation
Material very appreciated by users especially for its management of hygrometry.