Environmental Education Center

Last modified by the author on 29/06/2019 - 13:44

New Construction

  • Building Type : Other building
  • Construction Year : 2016
  • Delivery year : 2018
  • Address 1 - street : km 31 prés des jardins exotiques 11000 SALé, Maroc
  • Climate zone : [Csa] Interior Mediterranean - Mild with dry, hot summer.

  • Net Floor Area : 6 000 m2
  • Construction/refurbishment cost : 8 000 000 €
  • Number of none : 15 none
  • Cost/m2 : 1333.33 €/m2
  • Primary energy need
    259 kWhep/m2.an
    (Calculation method : Other )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

The Center for Environmental Education, adjoining the exotic gardens of Bouknadel, ... This is an operation initiated by the Mohammed VI Foundation for the Protection of the Environment, designed by Layla SKALI, accompanied on the environmental and development side by Bureau Veritas Morocco Group.

The CEE is an elegant building, contemporary very bright high-end; built in earth, bioclimatic design, made of raw materials assumed, it is at the forefront of technology serving ecology, well-being, comfort of use and health.

Another peculiarity for this project, which shows the evolution of organizational methods, especially thanks to digital. Technologies equip the building: Home automation, display screens of environmental indicators ...

A strong commitment to the environment
Another marker of this project, CEE is the first building testing the feasibility of setting up a Moroccan label for projects located in Morocco. Its architecture illustrates the commitment of the Mohammed VI Foundation for the protection of the environment and its partners in a process of sustainable construction and environmental labeling. The large glazed areas allow to work in natural light the maximum of time. High performance double glazing is equipped with blinds .......
Inside, the structure of the walls built in earth allows the storage of the heat and its slow restitution. The strength of this building is to achieve the objectives of Moroccan environmental labeling with a mostly isolated and efficient envelope, thanks to this combination of the inertia of the earth, the performance of glazing and home automation equipment. At the level of the outdoor gardens, 274 m² of photovoltaic panels of 168 modules provide the necessary energy for building operation and all its annexes with a coverage percentage of needs exceeding 90% (low demand) and more than 30 % (high demand). Finally, unlike Moroccan operations, a Wastewater Treatment Plant is installed to completely cover the watering needs of all the gardens and green spaces surrounding the Center.

Data reliability

Self-declared

Contractor

    Fondation Mohammed VI pour la protection de l'environnement

    KM,3,2 Route de Zaiers, avenue mohammed VI, rue EL MADANI IBN Houssaini RABAT

     https://www.fm6e.org/

Construction Manager

    LAYLA SKALI ARCHITECTE

    LAYLA SKALI architecte Rabat, Rabat-Salé-Zemmour-Zaër, Morocco

Stakeholders

    Other consultancy agency

    BET ETAM-ETUDES

    Abdelaziz Lazhari

    DESIGN STUDIES


    OCBM Ouminium de construction de batiment MAGHREB

    Route Des Zenatas - R.S. 111 (Cotiere), Casablanca 20100, Maroc

     http://www.ocbm.ma/

    Company in charge of the lot 1 big work waterproofing charm in wood and rammed earth


    EQUELEC

    QUARTIER INDUSTRIEL DOUAR DOUM-LOT18C RABAT-TAKADDOUM

     http://equelec.ma/home/

    strong and weak current, lift, air conditioning, ventilation Plumbing and sanitary -PCI


    ALIFBEL

    LOT JOINERY ALLUMINIULM, WOOD JOINERY, REMOVABLE PANELS


    GTPM

    PLASTER LOT AND PAINT


    REVPLOMB

    LOT COVER FLOOR AND WALL



    GHANI CONSTRUCTION

    LOT MENUISERIE METTALIQUES


    Assistance to the Contracting Authority

    Bureau Veritas Maroc

    Imm Sigma 4ème étage La Colline 20520, Casablanca

    Environmental assistance to the project management

Owner approach of sustainability

Mohammed VI foundation label for the protection of the environment based on international labels: LEED, HQE, BREEAM

Architectural description

A zero-loss passive architectural design meeting the targets below:

Eco - Construction: Integrated Choice of Processes and Construction Products / Clean Construction Site
Eco - Management: Energy / Water management, waste activities
Comfort: Hygro-thermal, acoustic, visual and olfactory
Health: Sanitary quality of spaces, air, water.
Expected results:
  • Realization of an ecological construction project inspired by Moroccan ancestral know-how in an environmental approach aiming at performance, energy efficiency and sustainability
  • Realization of an ecological construction project proposing a strong, functional and evolutionary integrated architecture.
  • Realization of an ecological construction project exploiting all renewable energy sources effective for the good operation of the center.
  • Obtaining an exemplary and demonstrative architecture, in terms of sustainable development, illustrating itself the ecological purpose. Rational exploitation of natural resources (land, water, air, wind), use of geothermal energy through a Canadian well, optimized water management, natural ventilation, use of wind power for point electricity generation (wind turbines), use of solar energy, solar street lights.

Energy consumption

  • 259,00 kWhep/m2.an
  • 449,83 kWhep/m2.an
  • Other

  • 81,99 kWhef/m2.an
  • Heating 2042.29 Kwh / year
    Cooling 41049 Kwh / year
    Interior lighting 38140,84 Kwh / year
    ventilation 139 712.05

    These data are based on a Dynamic Thermal Simulation study phase design (improved inputs and ambitious assumptions)

    the actual consumption differs from the theoretical consumption, we did not perform any dynamic thermal simulation in the execution phase, however we have energy meters communicated to a centralized technical management (see photos), they indicate a consumption (17 MWH) the building is not yet busy regularly, we can share the annual consumption at the end of 2019,
    The actual energy production by the installed PV system measured on June 13, 2019 is: 45 MWH in 2421 hours since system startup. (to see the photo)


Envelope performance

    Garden floor retaining wall: A 13 mm Placoplatre, 5 cm high density rock wool accompanied by a 1 cm layer of thermal insulation of mineral wool, 20 cm reinforced concrete covered with an extruded polystyrene insulation of 4 cm => U = 0.571 W / m2-K.

    Exterior Garden floor: A 13 mm Placoplatre, 5 cm high density rockwool with a 1 cm air gap, covered with 20 cm reinforced concrete => U = 0.616 W / m2-K

    Wall outside floor: Wall rammed from 80 to 100 cm, the option 80 cm was selected responding to the safeguards of the RTCM => U = 0.665 W / m2-K

    - Low floor on solid ground: Concrete slab of 15 cm with // Extruded polystyrene thermal insulation of 4 cm U = 0.658 W / m2-K
    - Intermediate floor: 10 cm polished concrete slab on a DAS 250 // a 60 cm plenum, and a 13 mm acoustic plasterboard U = 0.451 W / m2-K
    - Roofing: bituminous waterproofing layer // 7 cm high density rock wool insulation // one layer of R12 insulating foam and 3 cm fir decking U = 0.338 W / m2-K U < 0.65 W / m2-K ✓

    - Structural partition: 16 cm reinforced concrete U = 2,490 W / m2-K
    - Non-structural partition Garden level (classroom separation): Two layers of 26 mm plasterboard separated by rockwool insulation in 5 cm rigid panel U = 0.653 W / m2-K
    - Current non-structural partition: Two plaster plaster of 15 mm on a brick terracotta 6 holes of 7 cm. U = 1.630 W / m2-K
    - Glass partition: Simple glazing Stadio extra clear with aluminum joinery without thermal break. U = 5.788 W / m2-K
    - Curtain wall double glazing argon filling with aluminum joinery with thermal break: U = 1,4 * 0,95 + 4,719 * 0,05, Uw = 1,396 W / m2-K, U <3,30 W / m2 -K ✓ and FS = 0.34

Real final energy consumption

    20,00 kWhef/m2.an

    2 019

Systems

    • Heat pump
    • No domestic hot water system
    • Reversible heat pump
    • Roof-top
    • Nocturnal ventilation
    • Solar photovoltaic
  • 50,00 %
  • - TRAN chilled water pump with a net COP of 2.22 and an EER of 3.31 (cold power of 70.4 Kw and hot of 52.5 Kw)

    - TROX brand air handling unit certified EUROVENT

    Monocrystalline panels (LG MONO X 300)
    Capacity of the PV station 50 Kwhp
    GHG or CO2 avoided is 205 Kg / day
    Average production of 274 Kwh / Day

    A large photovoltaic field

Smart Building

    Centralized Technical Management, a monitoring system

GHG emissions

  • 178,71 KgCO2 /m2
  • Dynamic Thermal Simulation that gives the Ef consumption in Kwh / m² and a conversion to KgCO2 using the "CO2 equivalent" gas emission factors of the electricity consumption in each country proposed in the table below are

Comfort

    ODAMAT paint (ODASSIA): Ecolabel certified Interior and exterior paints and varnishes Indoor and outdoor paints and varnishes

    Ecolabels certificates are available

    Nous avons calculer les températures de l'air, Température radiante et opérative, ainsi que les heures d’inconfort et le d'humidité relative pour chaque type d'espaces, les calcules ont générés par pas d'une heure (sur une année = 8762 HEURES) : Pour les

    Double acoustic partitions PREGYPLAC DECO BA13 (type D72, thickness 48 mm) with insulation with a sound reduction index of 43 dB.

    compact panels of Natural Mineral Wool Ultracoustic P, KNAUF
    LAFARGE ACOUSTIK Continuous Ceilings (BD): high density fibreboard
    with perforations. An absorbent veil that improves acoustic absorption and also serves to filter the particles is laminated plates.

Product

    5000W air handling unit

    TROX / TKM50HE

    Table 'c21_spain.innov_category' doesn't exist SELECT one.innov_category AS current,two.innov_category AS parentFROM innov_category AS oneINNER JOIN innov_category AS two ON one.parent_id = two.idWHERE one.state=1AND one.id = '19'

    This recognized brand product has been accepted due to its performance, in addition to night ventilation to minimize the operation of the latter.


    LG MONOX 300

    LG

    Table 'c21_spain.innov_category' doesn't exist SELECT one.innov_category AS current,two.innov_category AS parentFROM innov_category AS oneINNER JOIN innov_category AS two ON one.parent_id = two.idWHERE one.state=1AND one.id = '3'

    Among the best photovoltaic systems

    This product has been recommended by the MOE, validated by the AMO environment and Appreciated by the whole team after installation is put into use.

Urban environment

The project site is on the national road km 31 near exotic gardens.

Building Environmental Quality

  • Building flexibility
  • works (including waste management)
  • acoustics
  • comfort (visual, olfactive, thermal)
  • waste management (related to activity)
  • energy efficiency
  • renewable energies
  • products and materials

Reasons for participating in the competition(s)

Mastery and optimization of solar gains


Over-night ventilation to avoid air conditioningOrganic gardens and vegetable garden

Phyto-purification of water / Filtering and treatment with plants,

Rainwater harvesting for watering

permeabilization of soilsA large photovoltaic field with real output that exceeds 30% of energy needs.

Building candidate in the category

Energie & Climats Chauds

Energie & Climats Chauds

Santé & Confort

Santé & Confort

Prix du public

Prix du public

Green Solutions Awards 2019 - Bâtiments
PDF

Share :
Author of the page

Saif Eddine Majdaoui


Other case studies

More

Contest

Green Solutions Awards 2019 - Bâtiments