New Construction

  • Building Type : Collective housing < 50m
  • Construction Year : 2016
  • Delivery year : 2017
  • Address 1 - street : Duque de Baena 20009 DONOSTIA, España
  • Climate zone : [Cfb] Marine Mild Winter, warm summer, no dry season.

  • Net Floor Area : 354 m2
  • Construction/refurbishment cost : 549 000 €
  • Number of Dwelling : 4 Dwelling
  • Cost/m2 : 1550.85 €/m2
  • Primary energy need
    87 kWhpe/m2.year
    (Calculation method : Other )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

Overlooking the bay of La Cocha is Villa Eulieta. This detached multi-family building has been designed under the Passivhaus Standard, although it has not been certified.

The building has a floor area of 441 m2 and consists of a first floor for garage and installations, and a ground, first and second floor with 4 dwellings.

The structure is made of reinforced concrete and Termoarcilla walls, wrapped in an XPS SATE, which forms a continuous insulation envelope. The flat roof is also insulated with XPS.

The airtightness has been solved by a layer of plaster plaster, protected from perforations by the installation chamber insulated with rock wool.

As can be expected, the views of the bay are translated into large windows facing north. To minimize energy losses, all windows are made of high-performance wood-aluminum carpentry and triple glazing with low-emissivity and argon gas in the chambers.

Indoor air quality is guaranteed with a double-flow mechanical ventilation system with high-efficiency heat recovery. The house has a community air-to-water aerothermal heat pump as a production system for air conditioning and DHW. Given its passive design and north orientation, the building is cooled exclusively by passive means.

See more details about this project

 https://passivehouse-database.org/index.php?lang=en#d_6268
 https://www.arkilan.com/index.php/portfolio-posts/goiegi-proyecto-y-direccion-de-14-viviendas-garajes-trasteros-y-locales-2-14/

Data reliability

Assessor

Photo credit

Arkilan Arquitectos

Contractor

Construction Manager

Stakeholders


    Environmental consultancy

    Oliver Style & Bega Clavero

    praxis[a]praxis-rb.com

     http://www.praxis-rb.com

    Passivhaus Consulting


    Construction company

    Ingeniera Eneka S.L



    Facility manager

    Iñaki Kerejeta

    Technical architect

Owner approach of sustainability

The objective of the promotion was the creation of 4 homes that met the Passivhaus standard, comfortable, healthy, and with almost zero energy consumption.

Architectural description

The structure is made of reinforced concrete and Termoarcilla walls, wrapped in an XPS SATE insulation, which forms a continuous insulation envelope. The flat roof is also insulated with XPS.

The hermeticity has been solved by means of a layer of plaster plaster, protected from the perforations by the installation chamber insulated with rock wool.
The views of the bay are achieved thanks to the large windows facing north. To minimize energy losses, all the windows have high-performance wood-aluminum frames and triple low-emission glass with argon gas in the chambers.

Energy consumption

  • 87,00 kWhpe/m2.year
  • 178,80 kWhpe/m2.year
  • Other

Envelope performance

  • 0,30 W.m-2.K-1
  • U solera = 0.16 W / m2K
    U muros = 0.14 W / m2K
    U cubierta = 0.17 W / m2K

  • 0,38
  • n50

  • 0,21

Systems

    • Heat pump
    • Heat pump
    • No cooling system
    • Double flow heat exchanger
    • Heat pump

    Use of high-efficiency air conditioning technology, with simple and reliable solutions:
    - Air conditioning: Aeorthermic heat pump production system, air-water type, centralized for the 4 homes. No active cooling.
    - Ventilation: Zehnder ComfoAir 200 dual flow mechanical ventilation system, individual per home

GHG emissions

  • 100,00 year(s)

Indoor Air quality

    Air quality is ensured with the Zehnder ComfoAir 200 very high efficiency dual flow mechanical ventilation system with heat recovery, individual per home.

Product

    ComfoAir Zehnder 200

    Zehnder

     https://www.zehnder.es/

    Climatización / Ventilación, refrigeración

    The highly efficient heat recovery ventilation system is from Zehnder and an individual system per home has been proposed. It is made up of a ComfoAir 200 ventilation machine per dwelling, ComfoWell silencers, and a network of internal distribution ducts and ComfoTube discharge and extraction nozzles.

    Dual-flow ventilation system with heat recovery brings indoor air quality and comfort to users


    Daikin Altherma heat pump

    Daikin

     https://www.zehnder.es/

    Climatización / Ventilación, refrigeración

Construction and exploitation costs

  • 548 920

Urban environment

The building is located in the Miraconcha area (Ayete), located on a hill in the city of Donostia - San Sebastián.

Building Environmental Quality

  • indoor air quality and health
  • acoustics
  • comfort (visual, olfactive, thermal)
  • energy efficiency

Reasons for participating in the competition(s)

  • Designed under the Passivhaus Standard: given its passive design and north orientation, the building is cooled exclusively by passive means
  • Great views of the bay with large windows facing north. To minimize energy losses, all windows are made of high-performance wood-aluminum carpentry and triple glazing with low-emissivity and argon gas in the chambers.
  • Indoor air quality is guaranteed with a double-flow mechanical ventilation system with high-efficiency heat recovery.

 

Building candidate in the category

Energy & Temperate Climates

Energy & Temperate Climates

Green Solutions Awards 2020-2021
PDF
 NZEB EECN comfort Zehnder ventilation air quality energy effiency

Share :
Author of the page

Oliver Style

CEO en Praxis Resilient Buildings


Other case studies

More

Contest

Green Solutions Awards 2020-2021