RenovActive
- by Sabine Pauquay
- /
- 2015-07-06 11:15:37
- /
- Belgique
- /
- 7344 / FR
Extension + refurbishment
- Building Type : Isolated or semi-detached house
- Construction Year : 1921
- Delivery year : 2015
- Address 1 - street : 1070 ANDERLECHT, Belgique
- Climate zone : [Cfb] Marine Mild Winter, warm summer, no dry season.
- Net Floor Area : 95 m2
- Construction/refurbishment cost : 190 000 €
- Cost/m2 : 2000 €/m2
-
Primary energy need :
57.7 kWhep/m2.an
(Calculation method : )
Building users opinion
Building occupied for 1 month, the occupants are delighted
See more details about this project
http://renovactive.velux.beData reliability
Assessor
Stakeholders
Contractor representative
Velux
http://velux.beOrganization of studies and renovation + financing
Troubleyn NV
http://www.troubleyn.netCompletion of work and coordination of certain subcontracted works
Designer
ONO Architectuur
http://ono-architectuur.bedevelopment of the renovation concept
Thermal consultancy agency
Daidalos Peutz
http://daidalos.beThermal and durability advice
Contractor
Foyer Anderlechtois
http://foyeranderlechtois.berenovation
Contracting method
General Contractor
Owner approach of sustainability
certification Active House label
Architectural description
Renovation of a three-facade house dating from the 1920s to bring it to high energy standards, while maximizing comfort. Aesthetic research linked to the original image of the garden city (characteristic of Brussels)
Energy consumption
- 57,70 kWhep/m2.an
- 202,24 kWhep/m2.an
- 131,00 kWhef/m2.an
- 1 300,00 kWhep/m2.an
Envelope performance
- 0,31 W.m-2.K-1
- 1,50
- 2,90
Systems
- Condensing gas boiler
- Water radiator
- Low temperature floor heating
- Condensing gas boiler
- No cooling system
- Natural ventilation
- Nocturnal ventilation
- Nocturnal Over ventilation
- compensated Air Handling Unit
- Solar photovoltaic
- 6,00 % Photovoltaic panels 4.86 m2 orients south - 900 Wp
Smart Building
Product
VELUX automated roof windows

VELUX
http://velux.beTable 'c21_spain.innov_category' doesn't exist SELECT one.innov_category AS current,two.innov_category AS parentFROM innov_category AS oneINNER JOIN innov_category AS two ON one.parent_id = two.idWHERE one.state=1AND one.id = '10'
Automated roof windows involved in ventilation strategy
Great ease of installation and operability by the occupants
Author of the page
Sabine Pauquay
Public Affairs Manager
Other case studies

House HQ1- Sant Cugat del Vâlles
- 06/02/2023
- /
- Oliver Style
- /
- 263

Learnlife Eco Hub: pop-up learning space
- 18/10/2022
- /
- Oliver Style
- /
- 837

I+D+I SORIA CAMPUS
- 25/11/2021
- /
- María Jesús González Díaz
- /
- 2751

Greenspace Gijon
- 23/11/2021
- /
- eladio rodriguez
- /
- 3296


Passive House for the Elderly
- 01/04/2021
- /
- José Miguel Asencio Asencio
- /
- 8006