Building EnergyPlus Orru

8084
Last modified by the author on 12/02/2013 - 19:27

New Construction

  • Building Type : Isolated or semi-detached house
  • Construction Year : 2010
  • Delivery year : 2010
  • Address 1 - street : 39028 SILANDRO, Italia
  • Climate zone : [Dwa] Humid Continental Hot Summer, severe, dry winter

  • Net Floor Area : 170 m2
  • Construction/refurbishment cost : 310 000 €
  • Number of Dwelling : 1 Dwelling
  • Cost/m2 : 1823.53 €/m2

Certifications :

  • Primary energy need
    5 kWhpe/m2.anno
    (Calculation method : UNI TS 11300 )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

Passive House and Klimahaus Gold Plus, Passive House and CasaClima Oro Più, annual energy requirement of 3 kWh / m2a, 170m2 net, infrared electric heating system (1.5kW), 5.6kW photovoltaic system, solar thermal system, thermal coat 20cm rockwool, triple glazing fixtures.

See more details about this project

 http://old.tekneco.it/progetto/abitazione-energy-plus/

Data reliability

3rd part certified

 http://old.tekneco.it/progetto/abitazione-energy-plus/

Contractor

Construction Manager

Stakeholders

Contracting method

Build and sell construction

Owner approach of sustainability

self-sufficient building with almost zero environmental impact

Architectural description

3-storey single-storey terraced building, sustainable materials on the outside and inside, free of thermal bridges. 1,5kW infrared electric heating system, photovoltaic system, thermal soles plant, controlled mechanical ventilation system with heat recovery, clay plaster

If you had to do it again?

Anything

Building users opinion

very comfortable, nothing management expense

Energy consumption

  • 5,00 kWhpe/m2.anno
  • 30,00 kWhpe/m2.anno
  • UNI TS 11300

Envelope performance

  • 0,25 W/m2K
  • coat walls 20cm rockwool U 0.17
    roof 32cm wood fiber U 0.14
    Slab towards cellar 15cm perlite U 0.24

  • 0,43
  • DIN 4108-7

  • 0,60

Real final energy consumption

    2 017

Systems

    • Electric heater
    • Individual electric boiler
    • No cooling system
    • Double flow heat exchanger
    • Solar photovoltaic
    • Solar Thermal
  • 100,00 %

GHG emissions

  • -9,00 KgCO2/m2/anno

Product

    Self-sufficient electric heating system

    Paolo Orru

    [email protected]

     www.energyconsulting.eu

    HLK / Heizung, Warmwasser

    Self-sufficient residential building

    Excellent comfort, zero operating costs

Construction and exploitation costs

  • 310 000

Urban environment

Inserted in a complex of terraced buildings

Building Environmental Quality

  • indoor air quality and health
  • biodiversity
  • acoustics
  • comfort (visual, olfactive, thermal)
  • energy efficiency
  • renewable energies

Building candidate in the category

Energia e Climi Temperati

Energia e Climi Temperati

Utenti Preferito

Utenti Preferito

Green Solutions Awards 2018 - Edifici
PDF

Share :
Author of the page

Paolo Orru

Engineer


Other case studies

More

Contest

Green Solutions Awards 2018 - Edifici