Cholet Motorcycles

8751
Last modified by the author on 23/04/2014 - 09:37

New Construction

  • Building Type : Store in a shopping mall
  • Construction Year : 2013
  • Delivery year : 2014
  • Address 1 - street : 49300 CHOLET, France
  • Climate zone : [Cfb] Marine Mild Winter, warm summer, no dry season.

  • Net Floor Area : 750 m2
  • Construction/refurbishment cost : 403 000 €
  • Number of Visitor : 100 Visitor
  • Cost/m2 : 537.33 €/m2

Certifications :

  • Primary energy need
    59 kWhep/m2.an
    (Calculation method : Other )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

Construction of a motorcycle passive store with a construction cost of 570 € HT/m².

Since the delivery in mid-January 2014 the heating has not been put into operation for an internal temperature never lower than 16 ° C.

Sustainable development approach of the project owner

The goal was to build a passive building at the same price as a RT2012 (French thermal regulation for buildings) building. The construction budget is 570 € HT per m2. It should be noted that the client did not know what a passive building was when the prime contractor was chosen.

Architectural description

Metal structure, sandwich panels in front, joinery type stabalux triple glazing, waterproofing cover, n50 = 0.15

Building users opinion

Perfect thermal comfort due to the absence of cold walls and the absence of parasitic air currents. A very pleasant acoustic comfort due to the very good air tightness and triple glazing.

If you had to do it again?

Particular attention should be paid to summer comfort. The customer found the installation of external blinds superfluous, which will certainly be realized before the summer

See more details about this project

 http://www.equipe-ingenierie.fr/nos-realisations/

Stakeholders



Contracting method

Separate batches

Type of market

Table 'c21_germany.rex_market_type' doesn't exist

Energy consumption

  • 59,00 kWhep/m2.an
  • 110,00 kWhep/m2.an
  • Other

    According to PHPP calculation: - Heating: 18% - DHW: 25% - Lighting and technical equipment: 48% - Auxiliary: 9%

Real final energy consumption

    110,00 kWhef/m2.an

    25,60 kWhef/m2.an

    2 014


    21,00 kWhef/m2.an

    2 015


    21,70 kWhef/m2.an

    2 016

Envelope performance

    Outer walls: U = 0.103 W.m2.K-1
    Roofs: U = 0.143 W.m2.K-1
    Floors: U = 0.172 W.m2.K-1
    Aluminum joinery: Uw = 0.76 W.m2.K- 1.

  • 0,55
  • n50

  • 0,15

More information

Calculation of energy Primary calculated according to the certified PHPP sheet (passive construction). Actual measured consumption The building at the time of the building permit was submitted only to RT2005.

Systems

    • Electric radiator
    • Individual electric boiler
    • No cooling system
    • Double flow heat exchanger
    • No renewable energy systems

    Les façades sud et Ouest ont été très vitrées pour l'exposition client et bénéficier des apprts solaires

Smart Building

    none

Urban environment

  • 725,00 %
  • Downtown Construction

Product

    Dual flow ventilation KWL EC 1400 D

    HELIOS

    01 48 65 75 61

     https://www.helios-fr.com/

    Table 'c21_germany.innov_category' doesn't exist SELECT one.innov_category AS current,two.innov_category AS parentFROM innov_category AS oneINNER JOIN innov_category AS two ON one.parent_id = two.idWHERE one.state=1AND one.id = '19'

    High efficiency dual flow ventilation

    The unit is certified by Passivhaus Institute, 82% efficiency

Construction and exploitation costs

  • 35 000
  • 403 000

Energy bill

  • 1 600,00

Indoor Air quality

    Dual-flow central unit controlled by the CO2 rate of the sales area: CO2 content less than 650ppm / m3

Building candidate in the category

Energie & Climats Tempérés

Energie & Climats Tempérés

Coup de Cœur des Internautes

Coup de Cœur des Internautes

Green Solutions Awards 2017 - Bâtiments
PDF

Share :
Author of the page

Tugdual ALLAIN

Gérant


Other case studies

More

Contest

Green Solutions Awards 2017 - Bâtiments