Bois Debout

  • Building Type : Collective housing < 50m
  • Construction Year : 2015
  • Delivery year : 2016
  • Address 1 - street : 34 rue Girard 93100 MONTREUIL, France
  • Climate zone : [Cfb] Marine Mild Winter, warm summer, no dry season.

  • Net Floor Area : 1 323 m2
  • Construction/refurbishment cost : 1 990 000 €
  • Cost/m2 : 1504.16 €/m2

Certifications :

  • Primary energy need :
    49 kWhep/m2.an
    (Calculation method : RT 2012 )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

17 social housing + business premises in Montreuil sous bois (93). 940m² of living space. Wood-frame building on 6 levels full dry system (screeds and elevator shaft in CLT). Certification passiv haus level and Paris Climate Plan level without ENR. Owner: Grand Paris Habitat for Osica SNI. Architects: Stéphane Cochet + Bruno Garnier.

Data reliability

3rd part certified

Stakeholders

    Designer

    A003architectes

    contact@A003architectes.com

    agent architect


    Manufacturer

    SOCOPA construction ossature bois

    jean-luc.marchal@constructions-socopa.fr

    cover closed


    Designer

    BGA architecture

    bruno.garnier_archi@orange.fr

    associate architect


    Thermal consultancy agency

    AMOES

    contact@amoes.com

    Thermal Fluid + + QEB


    Structures calculist

    S2T

    stephane.pierra@s2t.fr


    Environmental consultancy

    Cabinet Joel LOT

    stephane.pierra@s2t.fr

    Economist


    Contractor

    Grand Paris habitat

Contracting method

Macro packages

Owner approach of sustainability

First goal: building a certified passiv haus building in addition to the H&E Cerqual certification. Proposal project management of all wood framing on 6 levels. Desire to control the loads of energy consumption and maintenance maintenance (P1 costs / P2 / P3)

Architectural description

Building installation on two former plots in dense urban center. architectural composition within the old parcel tracing around a two-part composition. typical architectural Writing suburb of architecture. aligned front, penthouse, pass box, cage lit staircase naturally. through housing off T1, North / South orientation. Work on summer comfort, the fight against heat islands (cool roof roof). No ENR, no radiator. reduced technical equipment (boiler of 24kW for all dwellings, a comfort ventilation to recovery centralized heat, static heat recovery units on waste water in each unit). Work at the plot level on biodiversity, shared garden and edible garden.

If you had to do it again?

We show through this project it is possible to build an all wooden building on 6 levels certified passive to an equivalent price than building a concrete level RT2012 construction. Cost control P1 / P2 / P3 with very little equipment: a 24kW condensing boiler for the EC and the SAT 17 housing and a comfort ventilation to recovery centralized heat.

Building users opinion

energy and sociological monitoring of the building and its uses for 3 years as part of the agreement with ADEME IDF

Energy consumption

  • 49,00 kWhep/m2.an
  • 75,00 kWhep/m2.an
  • RT 2012

  • 63,00 kWhef/m2.an
  • 12% Heating / Hot Water 23% / 6% Lighting / 17% following RT Auxiliary

    103kWh.ep / m².yr following PHPP

Envelope performance

  • 0,28 W.m-2.K-1
  • Bbio gain of 22 70%

  • 0,57
  • n50

  • 0,30
  • No home automation installed apart in the building energy monitoring in place (instrumentation) as part of the ADEME convention for the measurement campaign and monitoring of 3 years on building on 5 RT positions.

Systems

    • Condensing gas boiler
    • Condensing gas boiler
    • No cooling system
    • Double flow heat exchanger
    • No renewable energy systems
  • centralized 24kW boiler for EC production and Hot water of 17 apartments and a comfort ventilation to centralized heat recovery. One loop of hot water. individualized cylinder on hydraulic exchanger.

    Static heat recovery from waste water outlets controlled, Hot water arrival on washing machine

GHG emissions

  • 895,00 KgCO2/m2/an
  • like carbon balance sheets from the FDES materials

  • 12,00 KgCO2 /m2
  • 50,00 an(s)
  • 906,00 KgCO2 /m2
  • 315kg eqCO2/yr

Life Cycle Analysis

  • 15 769,00
  • 350m3 of wood used, building organically sourced label

Indoor Air quality

    SW3

Health & Comfort

    20% glass area on SHAB m², through housing / A + VOC materials / triple glazing no cold wall / no cold air coming into carpentry (VMC double flow) / manual occultations openwork for summer comfort

    20°C winter comfort, overheat >25°C < 3,4°C according to PHPP

    Cerqual Qualitel H&E label

Product

    Alkorbright

    Renolit

    RenolitFrance-Toiture@renolit.com

    Rohbau / Teppich, Beschichtung, Beläge, Dichte

    _ cool roofing roof waterproofing membrane

    under technical opinion

Construction and exploitation costs

  • 242 325
  • 3 160 276
  • 250 804

Energy bill

  • 6 800,00

Urban environment

urban city center, inner suburbs of Paris, site forced narrow street joint, demolition of two existing buildings including town house R + 1 and hangar. Built biodiversity vegetated northern facade with climbing (hydrangea) valley planted with fruit shrubs (cassisiers, currants, strawberries), fruit trees (pear), vegetable patch. Retrieving EP for watering and maintenance. Fight against the islets of heat roofing membrane with high solar reflectance of power (albedo 0.8) + evapotranspiration of vegetated northern facade.

Land plot area

350,00 m2

Built-up area

74,00 %

Green space

60,00

Parking spaces

Cycling - 25m²

Building Environmental Quality

  • indoor air quality and health
  • biodiversity
  • works (including waste management)
  • acoustics
  • comfort (visual, olfactive, thermal)
  • waste management (related to activity)
  • water management
  • energy efficiency
  • maintenance
  • building end of life management
  • integration in the land
  • building process
  • products and materials
 Wood-frame building on 6 levels full dry system (screeds and elevator shaft in CLT), Passiv Haus certification, bâtiment label bio-sourcé niveau 3, lauréat appel à projet ADEME IDF Bepos/Bepas 2013, lauréat du OffDD2015. Travail sur biodiversité batie et résilience urbaine. Construction "Low Tech" sans ENR. Approche en coût global P1/P2/P3 maîtrise des consommations énergétiques et des charges en entretien maintenance sur DVT de 30ans.

level 3 bio-based labelled building, chosen by ADEME for a call for proposals (BEPOS/BEPAS 2013 project), OffDD2015 award winner . Work on biodiversity and urban resilience. Low Tech construction without renewables. Global cost approach P1 / P2 / P3, controlled energy consumption and maintenance costs over 30 years.

Contest categories

Energie & Climats Tempérés

Energie & Climats Tempérés

Coup de Cœur des Internautes

Coup de Cœur des Internautes

Green Solutions Awards 2017 - Bâtiments


Author of the page

  • Stéphane Cochet

    architecte libéral


  • Other case studies

    More

    Contest