Zenale Building

9904
Last modified by the author on 27/06/2017 - 11:25
  • Building Type : Collective housing < 50m
  • Construction Year : 2012
  • Delivery year : 2012
  • Address 1 - street : 20123 MILANO, Italia
  • Climate zone : [Cfb] Marine Mild Winter, warm summer, no dry season.

  • Net Floor Area : 3 000 m2
  • Construction/refurbishment cost : 4 000 000 €
  • Number of Dwelling : 12 Dwelling
  • Cost/m2 : 1333.33 €/m2

Proposed by :

  • Primary energy need
    kWhpe/m2.anno
    (Calculation method : )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building
​The intervention involves the complete renovation of a 1901 building in the historic center of Milan. The building thatHas a "L" shape and overlooks an inner courtyard, spreads over five floors and houses flats, laboratories and new shops on the ground floor.On the outside as well as for the restoration of the existing façades, a new prospect faces the neighboring garden. At the center of this front is created a full-height recess that accommodates the loggia and creates the feeling of being faced with two distinct factory buildings: a brick tower with views of the park's openings and a classic facade that goes on camouflaging The street front.The formal result obtained allows the building to integrate harmoniously with architectural preesistence.The loggias, which are born in the new cavity, are characterized by a steel parapet arranged for the placement of plants and flowers; On the top floor instead a terrace is created that highlights the gap between the two volumes. The intervention on the inner court is aimed at ensuring visual continuity between the road and the inner park thanks to the large glazed openings that bring air and natural light even in the underground spaces of the building.In the building a new enclosure insulation and modern plant solutions such as a water heat pump and radiant floors have been set up to provide maximum thermal comfort for users with minimal energy consumption.
Credits:
  • CUSTOMER
Real Estate Zenale S.r.l
  • DESIGN AND DL
Arch. Filippo Taidelli
  • PARTNER
Arch. Piero Castellini
  • GENERAL CONTRACTOR
Coima Project S.r.l.
  • WOODEN WORKS
Ori & Bonetti
  • INSTALLATIONS
Manens Intertecnica
  • GEOTHERMAL
Ing. Stefano Sesana
  • STRUCTURES
Enco Engineering ConsultingcalculationsStudio Three
  • SAFETY
Arch. Carmine Concas
  • PHOTOGRAPHER
Andrea Martiradonna
  • COLLABORATORS
Marta Brambilla, Josè Bove, Elisa Castelli, Roberto Leva, Francesco Nava, Franco Bucci, Claudia Brunelli, Vincenzo Cuozzo, Luigi Martinelli

Data reliability

Self-declared

Stakeholders

    Contractor

    Immobiliare Zenale S.r.L.

    Corso Vittorio Emanuele 9 - 20122 Milano





    Thermal consultancy agency

    Manens Intertecnica S.r.L.

    Via Campofiore 21 - 37129 Verona


    Structures calculist

    Enco Engineering Consulting S.r.L.

    Via Carlo Urbino 52 - 26013 Crema (CR)


    Others

    Studio Dott. Geol. Stefano Sesana

    S.S.dei Giovi 22 - 22070 Vertemate con Minoprio (CO)

Contracting method

General Contractor

Systems

    • Geothermal heat pump
    • Low temperature floor heating
    • Condensing gas boiler
    • Heat pump
    • Geothermal heat pump
    • humidity sensitive Air Handling Unit (hygro A
    • Heat pump (geothermal)

Construction and exploitation costs

  • 4 000 000

Land plot area

630,00 m2

Built-up area

74,00 %

Building Environmental Quality

  • energy efficiency

Building candidate in the category

Energy & Temperate Climates

Energy & Temperate Climates

Users' Choice

Users' Choice

Green Solutions Awards 2017 - Buildings
PDF

Share :
Author of the page

Filippo Taidelli Architetto


Other case studies

More

Contest

Green Solutions Awards 2017 - Buildings