Troni Brien House in the mountains

  • Project type : New Construction
  • Building Type : Terraced Individual housing
  • Construction Year : 2014
  • Delivery year : 2015
  • Climate zone : [Csa] Interior Mediterranean - Mild with dry, hot summer.
  • Net Floor Area : 275 m2
  • Construction/refurbishment cost : 315 000 €
  • Number of Dwelling : 1 Dwelling
  • Cost/m2 : 1 145 €/m2
  • Cost/Dwelling : 315 000 €/Dwelling


Moderated by : Clément Gaillard

Similar case studies

Passivistas:TheHouseProject

The existing building, a typical 1960´s Athens single-family house, was selected for a full refurbishment using Passivhaus standards. The bearing structure was originally made by reinforced concrete with no insulation in the walls (...)

"Les Charmilles" residence

· Building certified BBC Effinergie The operation “Les Charmilles” with twenty-eight housings in the town of Jouques is the first BBC operation by the social landlord Famille & Provence as contractor. The design of this project was (...)

Vermont House (ECOXIA Intelligent Envelope )

House model to demonstrate the interest of the ECOXIA intelligent envelope for manufacturers:Energy Performance (positive energy with only 20m² of solar panels)quality of indoor aireco-construction (wood)and many other welfare feature (...)


  • Published on 04 June 19
    by Arquiambiente Ltda|International
    Viewed 1107 times
  • Proposed by :




  • Contest

    Green Solutions Awards 2019 - Buildings

    Energy & Temperate Climates
    Health & Comfort
    Users' Choice


    ​The house is located on an artificial terrace carved into the hill, joining it and facing north, taking advantage of exceptional sunlight conditions and privileged views of the valley.

    These conditions required to project a north facade with large windows to enjoy the view and solar gains in winter, protected by eaves which provide shade and prevent overheating in summer. Besides a large sun roof that covers 100% of the electricity demand and a surplus of electrical energy is injected into the public electricity network. 76% of the hot water demand it is projected.

    The energy demand and consumption were determinedtrough PHPP software according to all Passivhaus requirements. Additionally tocalculate the Zero Energy balance a specific consumption profile was createdaccording to the expected Family activities and renewable energy systems wereintegrated in the design.

    Thesolar thermal and photovoltaic systems contributions are 5.070 [kWh/y] and12.743 [kWh/y] correspondingly, based on calculations performed with Dr. Valentin Energie Software GmbH.



    Certification Scheme


    Location

    Camino a Farellones 40601 Lo Barnechea , 76900 Santiago Chile

    Technicals Features