Rchlo Ipanema CT - Filial 269

4260
Last modified by the author on 14/06/2019 - 04:06
  • Building Type : Downtown store
  • Construction Year : 2015
  • Delivery year : 2015
  • Address 1 - street : 22410001 RIO DE JANEIRO, Brazil
  • Climate zone : [Aw] Tropical Wet & Dry with dry winter.

  • Net Floor Area : 1 304 m2
  • Construction/refurbishment cost : 4 422 483 €
  • Number of Visitor : 186 Visitor
  • Cost/m2 : 3391.47 €/m2

Proposed by :

Certifications :

  • Primary energy need
    369.8 kWhpe/m2.year
    (Calculation method : Primary energy needs )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building
​On December 10, 2015, Riachuelo opened its first store in the Ipanema neighborhood, in Rio de Janeiro. The unit occupies the building where the iconic Chaika Cafeteria operated. With 1,378 m² of constructed area.
The store is the first LEED (Leadership in Energy and Environmental Design) certification process awarded by the U.S. Green Building Council (USGBC). Among the main sustainable initiatives are the installation of a rainwater reuse system, green roof deployment and the use of LED lighting.

See more details about this project

 http://vogue.globo.com/moda/moda-news/noticia/2015/12/riachuelo-inaugura-sua-primeira-loja-verde-em-ipanema-no-rio-de-janeiro.html
 http://www.blogdafal.com.br/2016/01/18/riachuelo-ipanema/

Photo credit

Studio Demian Golovaty

Contractor

Construction Manager

Stakeholders

    Construction Manager

    NOROESTE CONSTRUÇOES E EMPREENDIMENTO LTDA

    RENATO BARTOLOMEI

     https://www.ncel.com.br

    CONSTRUTORA E INSTALADORA


Contracting method

General Contractor

Type of market

Realization

If you had to do it again?

Innovative and motivating experience.

Building users opinion

A new experience where one can share the technology associated with the well-being of people without losing sight of the environment.

Energy consumption

  • 369,80 kWhpe/m2.year
  • 497,51 kWhpe/m2.year
  • Primary energy needs

    Lighting: 81.07 kWh/m2.year
    Equipment 78.74 kWh/m2.year
    Cooling: 38.96 kWh/m2.year
    Pumps and auxilary: 22,34 kWh/m2.year
    Fans: 27.94 kWh/m2.year
    Hot water: 7.38 kWh/m2.year
    Exterior usage: 0,32 kWh/m2.year

  • 6 500,00 kWhpe/m2.year

Envelope performance

  • 1,61 W.m-2.K-1
  • Walls U-value: 2.67 W/(m2*K)
    Roof U-value: 0.62 W/(m2*K)
    Windows U-value: 6.3 W/(m2*K)
    Skylight U-value: 6.3 W/(m2*K)
    For the envelope u-value were considered only the opaces surfaces

  • 0,15
  • I4

  • 10,00

Real final energy consumption

    256,81 kWhfe/m2.year

Systems

    • No heating system
    • No domestic hot water system
    • Water chiller
    • Fan coil
    • VRV Syst. (Variable refrigerant Volume)
    • Free-cooling
    • compensated Air Handling Unit
    • No renewable energy systems

    High efficiency chiller in cooling system. 66TR.

    100% LED lighting system / automation / air conditioning equipment in high efficiency and TAE with treated insufflation./Heat cover with heat sink.

Smart Building

    equipamentos de alta eficiência, iluminação led, vidros e cobertura com altor refletivos e isolação de calor, utilização de agua de chuva, todo um beneficio a favor de um bem estar, consciência em pró ao meio ambiente, retorno do investimento aplicado.

    benéfico, simples, arrojado e eficiente/objetivo.

Urban environment

    The RIACHUELO-Ipanema is a pleasant and healthy environment for employees and visitors, not only from an architectonic and decorative point of view. All indoor environments have the climatic conditions (temperature and air quality) and lighting ideal for all activities, with emphasis on optimizing the energy performance and operating costs of your energy systems (equipment and accessories), directly benefiting the company . Public access with comprehensive option, metro and bus. close to laser areas (beaches) and squares.

  • 382,00 m2
  • 100,00 %
  • 123,00

Product

    Lojas Riachuelo Conceito - certificação leed serie Gold

    FAL DESIGN E PROJETOS

    CLAUDIA BEIRÃO CARDOSO

     http://www.blogdafal.com.br

    Structural work / Structure - Masonry - Facade

    rainwater system
    100% led lighting system
    lighting and air conditioning system controlled by automation
    indoor / vertical landscaping.

    Innovative, model and of great satisfaction.
    The space, considered the first 'green store' of the network in Brazil, has several sustainable initiatives, among them the installation of a rainwater reuse system, the implementation of a green roof and LED lighting.

Construction and exploitation costs

  • 4 422 483,36
  • 2 915 563,20
  • 155 605,90
  • 196 555
  • 3 275 914
  • 523 080

Energy bill

  • 243 000,00

Life Cycle Analysis

Water management

  • 10,00 m3
  • 7,00 m3
  • 20,00 m3
  • Rainwater 15000lts
    3000lts Drinking Water
    Technical water fire 10000lt
    Potable water associated with 2500lts reserve of incentive
    Destination of water for basins and garden 2000lts

Indoor Air quality

    Sensor that measures the level of CO2, which aided by automation acts on the electric damper controlling the opening of the air renovation.

Comfort

    Glass facade and skylight series special anti-glare and heat sink, ensuring the translucent during daylight and insulating the heat layer.Slab with garden and waterproofing paint series special (white) insulation of actions to the solar rays giving the air of freshness to slab isolating the thermal load.Air conditioning and TAE with treated insufflation.

    400 a 700mmg/m3

    420mmg/m3

    Set temperature 23+-1°C

    23ºC

    Building in masonry with internal coating in Drywall and joinery.Equipment with motors and air vents with attenuators.

GHG emissions

  • 0,50 KgCO2 /m2
  • 250,00 year(s)
  • 81 500,00 KgCO2 /m2

Reasons for participating in the competition(s)

​AUTOMATION SYSTEM IN LIGHTING AND AIR CONDITIONING.

RAW WATER REUSE SYSTEM.

GREEN AREA AND VERTICAL GARDEN.

AUTOMATED GARDEN IRRIGATION SYSTEM

APPLICATION OF BASIC AND FINISH MATERIAL WITH CERTIFICATE OF ORIGIN.

Building candidate in the category

Energy & Hot Climates

Energy & Hot Climates

Users' Choice

Users' Choice

Green Solutions Awards 2019 - Buildings
PDF

Share :
Author of the page

Anderson Calvo da Silva


Other case studies

More

Contest

Green Solutions Awards 2019 - Buildings