Office Building of Hebei building science and technology research and Development Center

220
Last modified by the author on 25/06/2016 - 03:52

New Construction

  • Building Type : Office building < 28m
  • Construction Year : 2012
  • Delivery year : 2015
  • Address 1 - street : 050000 SHI JIAZHUANG, China
  • Climate zone : [Dwa] Humid Continental Hot Summer, severe, dry winter

  • Net Floor Area : 10 508 m2
  • Construction/refurbishment cost : 5 452 000 €
  • Number of Work station : 6 Work station
  • Cost/m2 : 518.84 €/m2

Proposed by :

Certifications :

  • Primary energy need
    113.2 kWhpe/m2.year
    (Calculation method : Primary energy needs )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building
The total construction area is 14527.17m2, underground area is 2164.87m2,6 floors area is 12362.3m2, the height of building is 23.55m, concrete framestructure, designed seismic intensity is 6 degrees;
Use features: the building is mainly used for newenergy-saving technology demonstration, energy technology research anddevelopment, testing, office and meeting rooms;
Construction standards: according to the German passivelow-energy buildings standards and China three-star green building standards.

Stakeholders


Contracting method

General Contractor

Type of market

Realization

Building users opinion

perfect contentment

Energy consumption

  • 113,20 kWhpe/m2.year
  • 120,00 kWhpe/m2.year
  • Primary energy needs

    heating, cooling, lighting, ventilation, hot water, equipement0.135

Envelope performance

  • 0,14 W.m-2.K-1
  • wall,200mm aerated concrete block+220mm Graphite polystyrene board ,reinforced concrete+220mm Graphite polystyrene board
    Window: Integral window heat transfer coefficient U≤1.0
    Door: Integral window heat transfer coefficient U≤1.0
    roof:100mmreinforced concrete+230mmXPS,K=0.14
    floor:100mmreinforced concrete+230mmXPS,K=0.14

  • 0,16
  • EN 13829 - n50 » (en 1/h-1)

  • 0,20
  • The fresh air system is automatically operated according to the concentration of carbon dioxide in the room
    Air conditioning system frequency conversion operation, indoor part according to the indoor temperature automatic operation
    Public lighting by sound and light control

More information

All of the above energy demand data are Used Germany PHPP calculation

Real final energy consumption

    37,70 kWhfe/m2.year

    107,85 kWhfe/m2.year

    35,95 kWhfe/m2.year

    2 015

Systems

    • Heat pump
    • Radiant ceiling
    • Fan coil
    • Solar Thermal
    • Fan coil
    • Radiant ceiling
    • Double flow heat exchanger
    • Heat pump (geothermal)
  • 15,00 %
  • Soil source heat pump and air to air conditioning system,Ground source side cold (hot) water cold (hot) direct supply fresh air units.

    The atrium two natural light well to strengthen the natural lighting and natural ventilation;Solar photovoltaic system,;solar hot water system

    Set ventilation roof,lighting roof, increase indoor lighting,strengthen natural ventilation

Smart Building

    Energy consumption of air conditioning fresh air system according to the feedback at the end of the automatic adjustment, itemized monitoring platform

     Automatic adjustable external shading

    Easy to use

Urban environment

    Volume rate of 1.3, the total construction density of 26.4%, green rate of 29.56%

  • 792 818,00 m2
  • 12,50 %
  • 234 357,00

Product

    passive house,York ,dena

    Hebei Academy of Building Research

    Email: [email protected]

     http://www.hebabr.com/

    Structural work / Passive system

    Being the very first passive-house office building in China, this project will play a huge role to promote the development of passive-house in Hebei and whole China, and which will improve the ecological environment and make the contribution to building a beautiful China in the future.

    This project has been recognized by the user, Dena and the community

Water management

  • 37 841,38 m3
  • 11 708,42 m3
  • 5 292,41 m3

Indoor Air quality

    Indoor temperature: summer 26℃,winter20℃;Carbon dioxide concentration ≤1000PPm

Comfort

    ≤1000PPm

    800~950

GHG emissions

  • 33,20 KgCO2/m2/year
  • 50,00 year(s)
PDF

Share :
Author of the page

shaoliang liu

engineer


Other case studies