Kindergarten Michel Ange in Amiens (BEPOS refurbishment)

14244
Last modified by the author on 26/05/2015 - 09:14

Renovation

  • Building Type : Preschool, kindergarten, nursery
  • Construction Year : 2012
  • Delivery year : 2013
  • Address 1 - street : 3, rue Michel Ange 80000 AMIENS, France
  • Climate zone : [Cfb] Marine Mild Winter, warm summer, no dry season.

  • Net Floor Area : 1 217 m2
  • Construction/refurbishment cost : 1 404 000 €
  • Number of Children : 200 Children
  • Cost/m2 : 1153.66 €/m2

Certifications :

  • Primary energy need
    51 kWhep/m2.an
    (Calculation method : RT 2005 )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

Energy refurbishment of Michel Ange School built in the 70s in order to transform it into a positive energy building as requested by the building owner which is the city of Amiens. 


Third Industrial Revolution: 

  • Energy Efficiency
  • Energy Producer Building

Sustainable development approach of the project owner

The city of Amiens wanted to refurbish the kindergarden of Michel Ange, by making the first positive energy refurbishment on the French territory. The goal is even more ambitious than the occupants are young children, whose comfort can not be neglected.
Rabot Dutilleul Construction Company has joined forces with SECA ENVIRONMENT agency, so as to offer to the city of Amiens an overall technical solution, incorporating both technical and structural constraints of a refurbishment, but also ambitious energy objectives.
The result: energy efficiency and sustainability beyond the initial specifications, in accordance with the budget.

Architectural description

Architect and general contractor- the city of Amiens.
The goal was to reach the BEPOS level for a very major refurbishment of the building, without much changes in the visual aspect of the building, excepting the roof.

Building users opinion

For the city of Amiens, the refurbishment of the kindergarten Michel Ange represents different challenges. First, a social issue, because this project helps to make children but also their parents, and more generally the educational sector, more aware of the energy saving needs.
The economic aspect is also important with energy savings estimated at 17,000 € per year for the school. The last issue is of course environmental; this renovation project is a part of a sustainable development policy and of the objective of reducing greenhouse gas emissions initiated by Amiens Métropole, seen in particular in this school, through the production of electricity using photovoltaic panels on the roof.
In the construction phase, the use of a general contractor was appropriate to ensure the overall goal. By high energy performances, Rabot Dutilleul Construction has committed to ensure the respect of the air tightness of the building envelope. To preserve this air tightness during the future maintenance operations, data sheets have been developed to raise awareness of the procedures to avoid any deterioration of the concept.

After over a year of functioning, if the savings are real, the expected results are somewhat skewed because of the creation of a recreational centre inside the school which had not been included in the simulations before work.

The observations also show that further efforts are required in terms of awareness and user education which behavior can lead to overconsumption. In conclusion, the energy refurbishment of the kindergarten Michel Ange into a positive energy building - a first case in Picardy - is a most successful experiment of Amiens Métropole, whose profits may be valued on future construction or renovation projects .
Jean CHEDRU, Head of Real Estate Heritage Service, Amiens Métropole.

If you had to do it again?

Rabot Dutilleul Construction wants to answer to new and ambitious consultations from an energy point of view, in line with the ambitions of North Pas de Calais about the Third Industrial Revolution.

See more details about this project

 http://www.picardie.ademe.fr/sites/default/files/files/Mediatheque/Publications/coup-vent-16-juillet-2013.pdf

Stakeholders




Contracting method

Macro packages

Type of market

Design and implementation

Energy consumption

  • 51,00 kWhep/m2.an
  • 106,00 kWhep/m2.an
  • RT 2005

    Heating: 28 Cooling and Hot Water: 0 Ventilation: 13 Auxiliary and lighting: 11 PV: 61

  • 160,00 kWhep/m2.an

Real final energy consumption

    -8,00 kWhef/m2.an

    16,00 kWhef/m2.an

    2 014

Envelope performance

  • 0,38 W.m-2.K-1
  • Thermal performance of joinery sets improvement: Uw = 1.3 W / m².K Insulation: Façades: pregyroche 50 + 10 + mineral wool (λ = 0.040) thick 150 mm / R = 5.59 m²K / W Roof: mineral wool ( λ = 0.041) thick 220 mm / R = 5.5 m²K / W

    I4

  • 0,73

More information

Within the context of PREBAT (Research and Experimentation Programme on Energy in the Building), aimed at experimenting with techniques and materials that will make the future reference and to anticipate future thermal legislation, ADEME launched calls for projects at the regional level for new constructions and for renovations.
As the first refurbished school at BEOPS level in Picardy, the Michel Ange school naturally had a particular interest for the Picardie Regional Directorate of ADEME.
With an ambitious technical specifications, beyond the eligibility criteria imposed by ADEME, this project was the subject of a monitoring consumption over the first year after the works, a procedure which at the time was not mandatory. After one year of use, analysis of ADEME shows that the school does not reach the level BEPOS according to a building producing more energy than it consumes. It is overconsumption 15 kWhEp / m².year beside the production. Several reasons explain this deviation from the forecast: First, the calculation toolkit is based on assumptions sometimes detached from the reality reality. The hot water consumption is a good example: While it is considered to be zero, the hot water actually represents 19% of building energy consumption. Furthermore, computer equipment or electrical appliances do not enter to the initial calculation. We must also take into account the behavior of users who are not necessarily aware of the energy savings which bad practices can lead to overconsumption (like poorly closed taps or lights that remain on). Despite this established discrepancy, the goal is not far and should be attainable after some adjustments and awareness. The results of the work on the Michel Ange school is very positive. The Michel Ange school is for ADEME an iconic operation, subject of numerous articles in internal publications and in the local press. The very positive feedback from users confirm the quality of the comfort of the building. Florent DUPUIS Engineer Building and Renewable Energy ADEME - Direction Régionale de Picardie

Systems

    • Condensing gas boiler
    • Water radiator
    • Other hot water system
    • No cooling system
    • Double flow heat exchanger
    • Solar photovoltaic
  • 107,00 %

Urban environment

    Classic urban environment of Amiens. Project of refurbishment without changing this environment

Product

    Membrane Vario Duplex

    ISOVER

    Resp Commercial

     http://www.isover.fr/Offre-produits/Catalogues-produits-ISOVER/Membrane-Vario-Duplex

    Structural work / Carpentry, cover, titghtness

    Membrane composed of a film based on polyamide grid laminated to a nonwoven web - Achieves excellent air tightness performance - Removes the risk of condensation in the lumber and promotes their drying - Compatible with bare and coated kraft wool

    Easy installation

Construction and exploitation costs

  • 123 000,00
  • 19 000
  • 1 440 000
  • 216 000

Energy bill

  • -1 500,00

GHG emissions

  • 7,00 KgCO2/m2/an
  • BET calculation

Reasons for participating in the competition(s)

​ENR : 200 m² de panneaux photovoltaïques en toitureRéhabilitation énergétique : Renforcement de l'isolation, par l'extérieurBatiment zéro énergie : substitution de la VMC originelle par une ventilation double flux.
Troisième Révolution Industrielle :- Efficacité énergétique- Bâtiment producteur d'énergie

Building candidate in the category

Renewable energies

Renewable energies

Low energy renovation

Low energy renovation

Net zero energy buildings

Net zero energy buildings

Green Building Solutions Awards 2015
PDF

Share :
Author of the page

Rodolphe Deborre

Directeur Innovation et Renaissance Ecologique


Other case studies

More

Contest