REEFLEX

21663
Last modified by the author on 21/05/2015 - 09:31

New Construction

  • Building Type : Student residence
  • Construction Year : 2014
  • Delivery year : 2015
  • Address 1 - street : 59650 VILLENEUVE D'ASCQ, France
  • Climate zone : [Cfb] Marine Mild Winter, warm summer, no dry season.

  • Net Floor Area : 14 500 m2
  • Construction/refurbishment cost : 21 400 000 €
  • Number of Dwelling : 539 Dwelling
  • Cost/m2 : 1475.86 €/m2

Certifications :

  • Primary energy need
    57 kWhep/m2.an
    (Calculation method : RT 2012 )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

REEFLEX is a different international student residence that combines residence and hotel residence. This unique concept meets the housing needs short and medium stay (a few nights to months) of students, international students under exchange agreement and visiting scholars.

The residence is part of the policy of the University of Lille in environmental and energy transition and respect for the environment, politics embodied in the Covenant (Think, Act, Building for environmental and energy transition University Lille) and Zero Carbon goal in the regional context of the third industrial revolution in Nord-Pas-de-Calais (TRI).

REEFLEX meets the profile of certification Habitat & Environment.

Sustainable development approach of the project owner

The sustainable development approach Rabot Dutilleul Construction is in line with that of the group Rabot Dutilleul. All operations we work on, are eco-designed with an AFNOR-certified ecodesign tool.
Here the REEFLEX residence : a living place designed to educate its inoccupants :
→ The architectural choices are explicit: differentiation of facades after a bioclimatic thoughtful approach between AMO and architects
→ The measuring equipment and support to track behavior in favor of the environment (see Reeflex website)

Architectural description

The architectural peculiarity and innovation lie in the simplicity of the design and the fact that the project was designed as an educational tool. Absence of complex envelope elements allows a compacity that serves both thermal performance and maintenance as well as the aesthetics of the project.

If you had to do it again?

Rabot Dutilleul Construction builds and designs such buildings every day with the goal to contribute improving territories as much as possible. Improvement in the meaning of 3 sustainable development pillars.
Especially in the Nord Pas de Calais region, the will to go further in the performance of Third Industrial Revolution: Renewable energies production and storage onsite, circular economy for the structural work.

See more details about this project

 http://reeflex.univ-lille.fr/Etudiant-Telecom/Appartements/

Stakeholders



    Designer

    Boyeldieu Dehaene Architectes

Contracting method

Other methods

 Conception Realisation

Energy consumption

  • 57,00 kWhep/m2.an
  • 94,00 kWhep/m2.an
  • RT 2012

    Heating: 19.2 kwhep / m² / year
    Cooling: 0 kwhep / m² / year
    Hot water: 30.5 kwhep / m² / year
    Lighting 3.2 kwhep / m² / year
    Auxiliaries 0.6 kwhep / m² / year
    Ventilation 5.1 kwhep / m² / year

Real final energy consumption

    53,00 kWhef/m2.an

Envelope performance

  • 0,53 W.m-2.K-1
  • Compositions of walls
    Walls with external insulation :
    16cm-thick concrete panel with external TH39 complement (11cm; foamed polystyrene) R ≥ 2,82 [m².K/W]

    Printd concrete wall with external insulation (only some parts of the groundfloor) :
    18cm-thick concrete panel with external TH39 complement (11cm; foamed polystyrene) and 7cm-thick printed concrete R ≥ 2,82 [m².K/W]

    Printed concrete wall with internal insulation (only in some parts of the groundfloor) :
    7cm-thick printed concrete wall, 18cm-thick concrete panel with 11cm-thick internal TH39 complement (foamed polystyrene). R ≥ 2,82 [m².K/W]

    Inner walls in non-heated rooms
    17cm-thick concrete panel with 8cm-thick TH34 complement (Calibel type or equivalent). R ≥ 2,35 [m².K/W]

    Low floor and low floor on terrace :
    20cm-thick reinforced concrete slab with 8cm-thick rigid TH34 insulation (foamed polystyrene). R ≥ 2,35 [m².K/W]

    Low floor in non-heated rooms or on the outside:
    20cm-thick reinforced concrete slab with 15cm-thick TH36 insulation under the slab (FibraXtherm type or equivalent). R ≥ 4,17 [m².K/W]

    Common roof
    20cm-thick reinforced concrete slab with 22cm-thick rigid TH34 external insulation (foamed polystyrene). R ≥ 6,47 [m².K/W]

    Steel trough roof (only on groundfloor)
    Steel trough with 22cm-thick mineral wool external insulation TH37 R ≥ 5,95 [m².K/W]

    Menuiseries aluminium à rupteurs de ponts thermiques intégrant un double vitrage (4/16/4 à remplissage Argon à 90%) pour les façades rideaux du rez de chaussée Uw = 1,6 [W/m².K]

    Double-glazed PVC joinery (4/16/4 Argon-filled 90%) and PVC roller shutters according to the architect's blueprints (in all bedrooms).
    Uw = 1,4 [W/m².K]
    U (roller shutters casings) = 2 [W/m².K]

    I4

  • 0,75

Systems

    • Urban network
    • Water radiator
    • Urban network
    • No cooling system
    • humidity sensitive Air Handling Unit (hygro A
    • No renewable energy systems

Urban environment

  • 28 150,00 m2
  • 4 300,00 %
  • 20 600,00
  • 5 minutes walk to the metro; the residence is located at the heart of the Lille University Campus.

Product


Construction and exploitation costs

  • 1 170 000
  • 21 400 000

Indoor Air quality

    Aqueous solvent-free paints were systematically used with heavy-metal-free mineral pigments. European Ecolabel was demanded, except in case it was impossible for the type of paint. Values ​​2010 European Directive 2004/42 / EC 4 on the limitation of VOC (Volatile Organic Compounds) are consistently met.

    We banned even labeled:
    - The products containing more than 2.5% of organic solvent and / or a VOC (volatile organic compounds) greater than 1.5 g / l of product.
    - Products containing pigments based on heavy metals (lead, cadmium, chromium).
    - Products containing glycol ethers classified as reprotoxic class II.

    Floor coverings:
    The falls have been recovered and stored in big bags and collected by the supplier specifically with recovery certificate. PVC flooring
    proposed must contain a minimum of 25% recycled material. Other types of soils were subjected to validation E. VOC and formaldehyde emission rate of these products are known and communicated to BE HQE. Flooring manufacturing factory certified ISO 14001.

    Indeed, for the housing of the residence, the floor is PVC-type category UP4 (recycled and natural) with zero tolerance vis-à-vis the emissions of volatile organic compounds. For commonplaces (movements, in living areas, ...), the majority of soil is tiled so no VOC emissions.

    "Our childcare center: a healthy space, a space of life"

    The coating of the crib will be without emission of volatile organic compounds and artificial green spaces are antibacterial certified to ensure good health of children who occupy it. These supports are specially designed for use in a nursery. Artificial grass is fire resistant, tear and easy to clean.

    The murals are also certified VOC.

GHG emissions

  • 21,00 KgCO2/m2/an

Life Cycle Analysis

Reasons for participating in the competition(s)

La résidence Reeflex : un lieu de vie pensé pour sensibiliser ses habitants :

  • Les choix architecturaux (différenciation des façades) sont issus d’une réflexion bio-climatique
  • Les équipements de mesure permettent de suivre son comportement en faveur de l’environnement

Les orientations environnementales

  • L’orientation Est/Ouest des façades est favorable à l’ensoleillement
  • La compacité et l’isolation de 11 cm des murs permettent d’être meilleur de 20% sur la RT 2012 (conforme au label Effinergie +)
  • Les larges baies permettent de dépasser le niveau de Facteur Lumière de Jour et de se passer de lumière artificielle pour 50% du temps.
  • L’apport en lumière est contrôlé par des volets roulants
  • Le choix de matériaux à faible impact environnemental (façade bois, matériaux non-polluants, revêtement de sol en PVC)

La vie intérieure de la résidence

  • Des circulations naturellement éclairées assurent la qualité d’ambiance
  • Une acoustique performante dans les parties communes et les logements conformément aux thématiques AI et AE du référentiel H&E
  • Un bâtiment entièrement accessible aux PMR conformément aux thématique Accessibilité du référentiel H&E
  • Des espaces extérieurs offrant des zones humides contribuant au confort d’été

Une maîtrise des consommations globales

  • Une consommation diminuée de 10 % par rapport à la RT 2012 (60 % pour la RT 2005) soit 10 000 €/an (50 000 €/an pour la RT 2005)
  • Les dispositifs de maîtrise des consommations électriques (interrupteur à badge) génèrent une économie de 5000 € /an
Troisième Révolution Industrielle :

  • Efficacité énergétique
  • Economie Circulaire

Building candidate in the category

Matériaux bio-sourcés et recyclés

Matériaux bio-sourcés et recyclés

Bâtiment zéro énergie

Bâtiment zéro énergie

Santé et confort

Santé et confort

Green Building Solutions Awards 2015
PDF

Share :
Author of the page

Rodolphe Deborre

Directeur Innovation et Renaissance Ecologique


Other case studies

More

Contest