ARGAN logistics platform - OXYLANE

4973
Last modified by the author on 03/09/2014 - 16:59

New Construction

  • Building Type : Logistics warehouse
  • Construction Year : 2013
  • Delivery year : 2013
  • Address 1 - street : Route Nationale 59220 ROUVIGNIES, France
  • Climate zone : [Cfb] Marine Mild Winter, warm summer, no dry season.

  • Net Floor Area : 57 129 m2

Proposed by :

Certifications :

  • Primary energy need
    97 kWhep/m2.an
    (Calculation method : RT 2012 )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building
  • Certified cycle: Construction
  • Certified phase: Design program
  • Global HQE rating: EXCELLENT
  • AFILOG Ranking:  2 Stars

The project consists of 54000 m² distributed on 9 storage cells on 2 wings connected by 1 550m² of offices and social areas. It is the 5th ARGAN operation certified “NF Bâtiment tertiaires – Démarche HQE” (French standard for tertiary buildings with high environmental quality approach) showing the qualitative approach adopted by ARGAN for its assets management strategy and its will to promote the project’s environmental component through certification.

 

 

Sustainable development approach of the project owner

• Certified cycle: Construction
• Certified phase: Design program
• Global HQE rating: EXCELLENT
• AFILOG Ranking: 2 Stars

It is the 5th ARGAN operation certified “NF Bâtiment tertiaires – Démarche HQE” (French standard for tertiary buildings with high environmental quality approach) showing the qualitative approach adopted by ARGAN for its assets management strategy and its will to promote the project’s environmental component through certification.
The project aims to provide a functional and well integrated site, controlled consumptions in the long term and a comfortable and healthy work environment. Pragmatic and controlled solutions are set up by placing the user at the heart of the building design.
Biodiversity
The project is the subject of a qualitative landscaped development in order to improve the biodiversity of the site which is a former agricultural plot. Many varieties were planted and total replanting of rainwater management pond was implemented/
Energy performance:
The envelope of the warehouse is insulated to limit heat losses through the walls, and all 87 platforms are equipped with external airlocks to limit air infiltration. The lighting of the cells is regulated according to the luminosity and controlled by motion sensor in the rack aisles.
Health and comfort
The user experience is highly improved by access to natural light and to thermal quality control. The heat treatment of the envelope associated with heating and cooling regulation systems helps to ensure control and stability of temperatures in the warehouse as in offices. The implementation of indoor covering products with low-COV emissions associated with efficient ventilation systems allows a healthy indoor environment for users.
Contributions of certification to the relations with the developer contractor and / or local authorities: Certification allows ensuring environment commitment of the contractor to the other stakeholders.
Contributions of certification to the operation and its actors: Certification gives to the contractor some assurance on the quality of the building whose the realization is entrusted to a builder-developer. This assurance is also useful for the building user since it helps to controlled operating costs and have many indirect advantages related to the working conditions of collaborators.

Architectural description

The project consists of 54000 m² distributed on 9 storage cells on 2 wings connected by 1 550m² of offices and social areas.
The building is mainly characterized by its qualitative access to natural light. The offices have a crossing access and the cells benefit from additional light thanks to many glazed openings on the façade contributing to significantly improve the visual atmosphere and giving view on the outside.

See more details about this project

 http://assohqe.org/hqe/IMG/pdf/fiche_operation_ARGAN_ROUVIGNIES.pdf

Stakeholders






Energy consumption

  • 97,00 kWhep/m2.an
  • RT 2012

    Primary energy needs for RT2012 only concern 1878m² of offices, social areas and outbuilding submitted to the RT2012.
    Primary energy needs of warehouses are calculated on the basis of the RT2005: 83.08 kWhEP/m².an (despite a recommanded temperature < 12 °C)

Systems

    • Individual gas boiler
    • VAV System
    • Individual electric boiler
    • Other hot water system
    • VAV Syst. (Variable Air Volume system)
    • Double flow heat exchanger
    • No renewable energy systems

    Ventilation: variable-delivrery double flow ventilation device, yield of 70%. CO2 sensor in intermittently-occupied rooms.
    Hot water: 1 electric cylinder and 1 thermodynamic cylinder

Water management

    Rainwater management pond

Indoor Air quality

    The implementation of indoor covering products with low-COV emissions associated with efficient ventilation systems allows a healthy indoor environment for users.