House of Solidarity of ORTHEZ (64) - Certified with label HQE BBC effinergie

13620
Last modified by the author on 25/03/2012 - 21:56
  • Building Type : Office building < 28m
  • Construction Year : 2010
  • Delivery year : 2010
  • Address 1 - street : 5 rue Jean Marie Lhoste 64300 ORTHEZ, France
  • Climate zone : [Cfb] Marine Mild Winter, warm summer, no dry season.

  • Net Floor Area : 1 762 m2
  • Construction/refurbishment cost : 3 800 000 €
  • Number of Work station : 70 Work station
  • Cost/m2 : 2156.64 €/m2

Proposed by :

Certifications :

  • Primary energy need
    35.4 kWhep/m2.an
    (Calculation method : RT 2005 )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

Built by the General Council of Pyrenees-Atlantiques, delivered in late 2010 and commissioning in early 2011, it includes all the institutional partners of the social action of Orthez.Ce 1761 m2 building, which houses seventy agents, is certified High Environmental Quality (HQE) NF tertiary buildings for all three phases (program, design and construction), ranked "outstanding" HQE and the international passport has been awarded the Low Energy Building, the 2005 level Effinergie BBC 12/01/2012.

Sustainable development approach of the project owner

HQE certified building referential label in 2010 with BBC effinergie 2005. Passport International Green Building ranked "outstanding" awards by CERTIVEA

Architectural description

Bioclimatic architecture orientated north-south, protected from prevailing winds.

Building users opinion

Very satisfied, this is another way to live in a building desktop. Very comfortable to use, for illumination and heating.The comfort of a summer is improving despite the GTB, comfort ventilation, and the Canadian well surventilation night.Indeed, this is a building with a very good performance of the air tightness 0.7, this performance also works the other way and any excess heat in the building in summer has trouble being evacuated.

If you had to do it again?

We will remake the same with even listen, the same team and the same ambitions.

See more details about this project

 https://plus.google.com/photos/106791329097613913996/albums/5688207457993885073

Stakeholders

    Contractor

    CONSEIL GENERAL DES PYRENEES ATLANTIQUES

    DAEE - Service Bâtiment - 05.59.11.44.93

     http://www.cg64.fr





Contracting method

Separate batches

Type of market

Global performance contract

Energy consumption

  • 35,40 kWhep/m2.an
  • 76,18 kWhep/m2.an
  • RT 2005

    CONSUMPTION 35.4 Kwh EP/m2/an 18.14 LIGHTING, HEATING 8.86; COOLING 0.65; In ECS + Elec. 0.44; AUXILIARY - WIND. 7.32

Real final energy consumption

    35,40 kWhef/m2.an

Envelope performance

  • 0,47 W.m-2.K-1
  • Sending the calculation RT 2005 on request by email.

  • 0,70
  • n50

  • 0,70

More information

GREENHOUSE GAS 2.91 0.59 KgeqCO2/m2/an LIGHTING, HEATING 2.05; COOLING 0.02; In ECS + Elec. 0.01; AUXILIARY - WIND. 0.24

Systems

    • Condensing gas boiler
    • Water radiator
    • No domestic hot water system
    • Others
    • Nocturnal Over ventilation
    • Double flow heat exchanger
    • Solar photovoltaic
    • Other, specify
  • 3,00 %

Smart Building

    GTB Support lightings, heating, alarms, ventilation DF, Canadian well .. grip a distance

Urban environment

  • 3 695,00 m2
  • 25,00 %
  • Located near the city center, opposite the station ensures continuity between the center and train station. The building is built to not interfere with the views of local residents. It possessed of green roofs and green walls.

Product

    Heating and cooling by the Canadian well with central dual stream, lighting autogradable to detection of presence, GTB

    HELIOS, PHILIPS, EES

    HVAC, électricité / ventilation, cooling

    Several systems in place: - Well with Canada's central turbofan - autogradable lighting with presence detection of wall-Plant-GTB performance

    Well Canada can receive a small difference between 10Â ° C outside temperature and that of the well (recuperationn summer and winter). The temperature of the building is very stable which can generate discomfort in summer when it's 24a ° C was hiring in the building. The GTB is a valuable tool but need the expertise in its use for construction and operation.

Water management

  • 70,00 m3
  • Water tank to regulate the flow of leaks, roofs, walls, vegetation and plant life.

Indoor Air quality

    Indoor air filter before arrival at the central double-flow networks with top quality, CO2 sensor in meeting room.

GHG emissions

  • 2,91 KgCO2/m2/an
  • Calculating Thermal Regulations 2005 - GHG calculations based on the energy consumed by different sources

  • 30,00 année(s)
  • 90,00 KgCO2 /m2

Life Cycle Analysis

    Materials evaluated in phase of study and attainment, with CCTP caracteriques has achieved in terms of emission of VOCs. The complete details of these materials can be supplied on request, it is listed with the case and the fact sheets have been formed for the HQE.

PDF

Share :