Creche Goult (84)

13498
Last modified by the author on 03/04/2012 - 14:57

New Construction

  • Building Type : Preschool, kindergarten, nursery
  • Construction Year : 2010
  • Delivery year :
  • Address 1 - street : Multi Accueil, Chemin des Lièvres 84220 GOULT, France
  • Climate zone : [Csa] Interior Mediterranean - Mild with dry, hot summer.

  • Net Floor Area : 380 m2
  • Construction/refurbishment cost : 886 037 €
  • Number of Children : 20 Children
  • Cost/m2 : 2331.68 €/m2
  • Primary energy need
    123.8 kWhep/m2.an
    (Calculation method : RT 2005 )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

Community of communes du Pont Julien wants to develop its policy in favor of youth and childhood. It therefore initiated discussions to determine the relevance of conducting a multi-host on its territory.

The construction of the crib Goult meets a real need by providing 20 nursery places on a time slot 11h. The study area is located in the Vaucluse, about 4 kilometers east of Gordes, on a former agricultural parcel grassy slopes slightly to the south.

The building at one level, includes: the crib, an open courtyard, outdoor spaces, roads and parking areas for staff and removal of children.

Sustainable development approach of the project owner

Accompanying the owner in his approach by BDM (Building Sustainable Mediterranean)

Architectural description

Joint deriving their roof slopes of steel trays on the North Slope and photovoltaic south.Floor roof terraces extending up the slopes of the DRC and sprockets.Attic feeders but not trafficable.Horizontal shading structure in the South.

See more details about this project

 http://www.polebdm.eu/sites/default/files/mod-le_rex_t-n-creche-goult.pdf

Stakeholders


    Construction Manager

    Jean-Jacques BRIEU


    Thermal consultancy agency

    ICOFLUIDES

Contracting method

Other methods

Energy consumption

  • 123,80 kWhep/m2.an
  • 270,00 kWhep/m2.an
  • RT 2005

    - Heating: 42.76 kWhep /an (34.5%)- Cooling: 12.92 kWhep / .an (9.58%)- ECS: 10.19 kWhep / .an (12.14%)- Lighting: 30.53- Auxiliary: 27.36

Envelope performance

  • I4

Systems

    • Heat pump
    • Low temperature floor heating
    • Radiant ceiling
    • Solar Thermal
    • Floor cooling
    • compensated Air Handling Unit
    • Double flow heat exchanger
    • Solar photovoltaic
    • Solar Thermal
  • 25 144,00 %

Urban environment

    The etude area is located in the department of Vaucluse, about 4 km lZest was not isolated, on a former agricultural parcel slight grassy slope to the south.