R&Roll Houses

17959
Last modified by the author on 06/04/2021 - 16:26

New Construction

  • Building Type : Terraced Individual housing
  • Construction Year : 2018
  • Delivery year : 2019
  • Address 1 - street : c/ Roll Menor, 48/50 46138 RAFELBUNYOL, España
  • Climate zone : [Csb] Coastal Mediterranean - Mild with cool, dry summer.

  • Net Floor Area : 516 m2
  • Construction/refurbishment cost : 639 324 €
  • Number of Dwelling : 2 Dwelling
  • Cost/m2 : 1239 €/m2

Certifications :

  • Primary energy need
    27 kWhpe/m2.year
    (Calculation method : Other )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

The R&Roll Houses project, the work of the architects Rafael Ortega Escrig and Raquel Marcos López belonging to the Spanish studio ra[]el Arquitectura, consists of two single-family houses between party walls, designed and built according to the principles of the PASSIVHAUS INSTITUTE using traditional concrete construction and brick, and insulated on the outside (SATE). Officially certified PASSIVHAUS PLUS in 2019, it is the first project of this type in the Valencian Community, promoted with the aim of being an energy-efficient building, technically and economically viable.

In order to also be a bio-healthy building, all construction processes have been developed to avoid toxic construction materials, electromagnetic fields and to reduce the carbon footprint through a responsible design with the environment.

It is important to note that the homes have a photovoltaic installation to produce the energy they need, as well as a gray water recovery system.

Based on the typical housing typology of the area and following contemporary aesthetic approaches, each house is organized facing an east-facing patio, which allows it to be used for almost the entire year. In this way, from the outside, two houses with a sober appearance are perceived, with a neutral upper body and the ground floor materialized as a round skin on which subtle indentations have been made that allow the entry of light while protecting privacy. of the users.

In the same way that special attention has been paid to the functional distribution of all spaces and the most profitable and efficient construction solution has been developed, the interior design responds to the careful study of every detail.

See more details about this project

 https://passivehouse-database.org/index.php?lang=en#d_5978

Data reliability

3rd part certified

Photo credit

Adrián Mora Maroto

Contractor

Construction Manager

Stakeholders

Energy consumption

  • 27,00 kWhpe/m2.year
  • Other

    Annual heating demand 10 kWh /(m2a ) calculated according to PHPP
    Heating load 10 W/m2
    PE demand (non-renewable Primary Energy) 57 kWh /(m2a ) on heating installation, domestic hot water, household electricity and auxiliary electricity calculated according to PHPP
    PER demand (renewable Primary Energy) 27 kWh /(m2a ) on heating installation, domestic hot water, household electricity and auxiliary electricity calculated according to PHPP
    Cooling load 11 W/m2
    Cooling and dehumidification demand 10 kWh /(m2a ) calculated according to PHPP

    Generation of renewable energy 59 kWh /(m2a ) based on the projected area

Envelope performance

    Exterior wall Plasterboard wall 26 mm
    Structure of galvanised sheet steel profiles
    Vapour control layer
    Autoclaved aerated concrete (AAC) 200 mm
    ETICS (rock wool panel 120 mm
    Outer finish
    U-value = 0.174 W/(m2K)

    Basement floor / floor slab Pavement 5 mm,
    Underfloor heating mortar 50 mm
    Plate UP788-25 25 mm
    Chovafoam 500 XPS 50 mm
    Concrete slab thickness minimum 60 mm
    Non-recoverable polypropylene formwork for ventilated screed
    U-value = 0.393 W/(m2K)

    Roof Gravel 100 mm
    Mortar 30 mm
    geotextile armed protection
    waterproof layer of EPDM
    Thermal insulation:double extruded polystyrene rigid boards (50+50)mm
    "Latermix Cem Classic" lightweight insulating permeable concrete 150 mm
    Floor of prefabricated concrete beams and extended polystyrene filler block 300 mm
    Gypsum 20 mm
    U-value = 0.18 W/(m2K)

    Frame SCHÜCO, Ventana Schüco AWS 75 SI
    Schüco AWS 75.SI+/ADS 75.SI
    Schüco ASE 80.HI
    U w-value = 1.19 W/(m2K)

    Glazing ClimaGuard Premium 2 6/12Kr/4/12Kr/4+4
    U g-value = 0.48 W/(m2K)
    g -value = 52 %

    Entrance door SCHÜCO
    frame Schüco AWS 75.SI + / ADS 75.SI
    Aluminum panel with 50 mm rock wool core.
    U d-value = 0.61 W/(m2K)

Systems

    • Heat pump
    • Electric floor heating
    • Heat pump
    • Tape
    • Double flow heat exchanger
    • Solar Thermal
    • Heat pump

    Gray water recovery system

Building Environmental Quality

  • indoor air quality and health
  • comfort (visual, olfactive, thermal)
  • water management
  • energy efficiency
  • renewable energies
  • products and materials

Building candidate in the category

Energy & Temperate Climates

Energy & Temperate Climates

Health & Comfort

Health & Comfort

Green Solutions Awards 2020-2021
PDF
 PassivHaus energy efficiency photovoltaic

Share :
Author of the page

Rafael Ortega Escrig


Other case studies

More

Contest

Green Solutions Awards 2020-2021