AttijariWafa Bank Drissia Business Center - Tangier

9683
Last modified by the author on 19/06/2019 - 15:34

New Construction

  • Building Type : Office building < 28m
  • Construction Year : 2019
  • Delivery year : 2019
  • Address 1 - street : bd Tarik Bnou Zyad, quartier Drissia 90070 TANGER, Maroc
  • Climate zone : [CsC] Interior Mediterranean - Mild & dry summer.

  • Net Floor Area : 528 m2
  • Construction/refurbishment cost : 650 000 €
  • Number of Work station : 13 Work station
  • Cost/m2 : 1231.06 €/m2

Proposed by :

Certifications :

  • Primary energy need
    141 kWhep/m2.an
    (Calculation method : RTCM )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

Being a building built on an environmental approach allowing a low consumption of energy and water, the reduction of atmospheric emissions and waste. This building houses 24 photovoltaic panels on its terraces covering 38% of its final energy needs and 100% of its lighting needs. The choice was also made on a ventilated facade.

See more details about this project

 https://www.construction21.org/maroc/articles/ma/le-centre-regional-d-attijariwafa-bank-a-tanger-drissia-certifie-hqe-excellent-phase-conception.html

Data reliability

Assessor

Contractor

Construction Manager

Stakeholders


    Company

    Airvent

    [email protected]

    Proposal of eco-friendly and energy efficient air conditioning systems. Ensures the correct installation of systems taking into account the prescribed sealing classes.

Contracting method

Separate batches

Owner approach of sustainability

- The Attijariwafa bank group has obtained the accreditation of the Green Climate Fund (GCF) from the United Nations Green Climate Fund (GCF) as a financial intermediary for the implementation of green financing in Africa. the only commercial bank in Africa and the MENA region, and the 7th largest commercial bank in the world to obtain this accreditation with regional coverage. The group stresses that the accreditation marks an important step in the CSR approach and support of the energy transition for Attijariwafa bank and will allow the bank to work in partnership with the Fund to support its public and private clients in their development projects. sustainable development on the African continent, through co-financing or guarantees of large-scale investments with a high impact, which may exceed 250 million US dollars per project.

- With this in mind, the group has set up, among other things, a waste management strategy for all its premises aimed at sorting them at the source and upgrading them by commissioning a sector for the collection and recovery of waste.

Architectural description

At the level of the facade, the masonry was carried out in double hollow brick partition 9 + 6 holes with incorporation of a thermal insulation of the type of rock wool and this in order to limit the effects of condensation on the outer walls in double partitions. This insulation also has a phonic role and will bring a better comfort to the users of the offices of the building. The facade has been treated with a durable coating in the form of ventilated facade allowing a free flow of air and a containment of water vapor.

The separation of spaces within the building is provided by removable glass partitions which gives the building a great capacity for adaptability and adaptation according to the change of use.

If you had to do it again?

RAS, since it was an existing building that was demolished and rebuilt in the state of the art considering the energy and environmental aspect

Energy consumption

  • 141,00 kWhep/m2.an
  • 278,00 kWhep/m2.an
  • RTCM

  • 72,00 kWhef/m2.an
  • Major consumer stations:
    - Lighting: 22,23kWh / m2
    - HVAC: 26.3 kWh / m2
    - Other (computer and auxiliary equipment): 32.37 kWh / m2

    The photovoltaic panels installed on the roof of the building make it possible to cover the specific consumption of the lighting station and up to more than 30% of the overall consumption of the building.

Envelope performance

  • 1,00 W.m-2.K-1
  • "- The aluminum joinery is executed with double glazing (6/12/6) with profiles with thermal break Ug = 1,1W / m2.K; Uw = 1,6 W / m2.K.
    - The roof of the building consists of a solid concrete slab, a thermal insulation made of agglomerated cork of 4cm and a sealing screen vapor barrier and bitumen felt 36s TV. "

Systems

    • Heat pump
    • Tape
    • No domestic hot water system
    • Reversible heat pump
    • Tape
    • compensated Air Handling Unit
    • Solar photovoltaic
  • 38,00 %
  • The photovoltaic panels have a nominal power of 275Wc.

    "- The cladding of the facade is done with a siding made of porcelain stoneware allowing the ventilation of the facade, thus avoiding the overheating of this one and reducing the needs in heating - A powerful glazing makes it possible to reduce the contri

Smart Building

    "All the equipment installed is Gtciables (DRV, Photovoltaics, electricity, pump lift, safety equipment, elevator ..).
    A GTB installation project is in progress (currently in the study phase), completion forecast for December 2019. "

GHG emissions

  • 22,00 KgCO2/m2/an
  • Retro-commissioning

Life Cycle Analysis

    55% of finishing materials are removable and easy to recycle

    80% of the elements of second and structural work have indicators of environmental impact according to the standard EN 15804 / ISO 21930

Water management

  • 48 088,00 m3
  • Double control 3 / 6L
    Washbasin 0,2 l / s
    sink (living space): 0,2 l / s

Indoor Air quality

    The materials and products applied to the project meet the international thresholds for C02 emissions inside the premises. 60% of the interior coatings are classified A +.

    Gaskets and finishing products have a hygienic character and are anti fungal treated. 80% of products in direct contact with air have emissions of TVOC <1000μg / m3 and formaldehyde <60μg / m3

Comfort

    All offices and coworking spaces have access to daylight and access to outside views.

    Air conditioning systems can be individually regulated by the occupants.

    11 800

    le facteur de lumière du jour dépasse 2% dans 80% des locaux occupés régulièrement.

Product

    Trane - TRV 5G DC Inverter

    Trane

     https://www.trane.com/commercial/europe/fr/fr.html

    Génie climatique, électricité / Ventilation, rafraîchissement

    TVR incorporates all functions necessary for filtration, cooling, heating and ventilation.
    The automatic adjustment of the system's energy consumption perfectly adapts the cooling load to the changing needs of all individual areas, thus saving energy.
    This system is quiet and has been mounted on an anti-vibratile base to ensure the acoustic comfort of the occupants.

    /

Construction and exploitation costs

  • 11 500,00
  • 570 000
  • 750 000

Urban environment

The building occupies 100% of the plot and has neither outdoor spaces nor parking. The site is well served by road and public transport and is close to the main points of the city of Tangier (marina, railway station, bus station, cornice ...).

The occupants can travel by public transport, by bike, carpool, something that promotes the modes of travel.

Land plot area

99,00 m2

Built-up area

100,00 %

Building Environmental Quality

  • Building flexibility
  • works (including waste management)
  • comfort (visual, olfactive, thermal)
  • waste management (related to activity)
  • energy efficiency
  • renewable energies
  • maintenance
  • products and materials

Reasons for participating in the competition(s)

The building was designed as part of a sustainable environmental approach, with a view to reducing its energy consumption (through the installation of photovoltaic panels), its water consumption (through the installation of hydro-efficient sanitary equipment ), its environmental impact (by the choice of eco-responsible materials and products) and in the aim of creating a healthy and comfortable interior for the occupants (by improving the hygrothermal conditions, the implementation of integrated management garbage...).

Intelligent building management will enable control, regulation and monitoring of environmental and energy indicators affecting the sustainable and healthy aspect of the building's interior space.

Building candidate in the category

Energie & Climats Chauds

Energie & Climats Chauds

Santé & Confort

Santé & Confort

Prix du public

Prix du public

Green Solutions Awards 2019 - Bâtiments
PDF

Share :
Author of the page

Ibtissam GHAZZAR

Ingénieur - Chef de projets


Other case studies

More

Contest