Ecolife Capitol

5073
Last modified by the author on 13/06/2019 - 16:31

New Construction

  • Building Type : Collective housing > 50m
  • Construction Year : 2015
  • Delivery year : 2018
  • Address 1 - street : 58 To Huu, Nam Tu Liem District 100000 HA NOI, Other countries
  • Climate zone : [Cwa] Mild, dry winter, hot and wet summer.

  • Net Floor Area : 53 476 m2
  • Number of Dwelling : 630 Dwelling

Proposed by :

Certifications :

  • Primary energy need
    kWhpe/m2.year
    (Calculation method : )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

Ecolife Capitol’s three high-rise residential towers introduced over 630 green apartments to the housing market in Ha Noi, Vietnam. To maximize energy savings and ensure occupant comfort, each of the apartments in the development are designed to maximize natural ventilation and feature low-flow plumbing fixtures, LED lighting and low-E double-glazed windows.

Ecolife Capitol was built by Capital House, a real estate investor dedicated to improving the resource efficiency of commercial and social housing through the use of energy-smart architectural design. Ecolife Capitol received final EDGE certification from SGS Vietnam.

See more details about this project

 https://www.edgebuildings.com/projects/ecolife-capitol/

Photo credit

Photos Courtesy of Capital House

Contractor

Construction Manager

Stakeholders

Energy consumption

    14 kWhfe/m2.year: hot water
    9 kWhfe/m2.year : Lighting
    4 kWhfe/m2.year : Common Amenities
    8 kWhfe/m2.year: Home appliances

Envelope performance

    Roof U-value: 1.7
    Wall U-value: 1.8
    Glass U-value: 5.4

Real final energy consumption

    34,69 kWhfe/m2.year

Systems

    • No heating system
    • Individual electric boiler
    • No cooling system
    • Natural ventilation
    • Solar photovoltaic
  • 0,84 %
  • Capacity kWp/Unit : 0.02

Product

    Reduced Window to Wall Ratio - WWR of 17%
    Reflective Paint for External Walls - Solar Reflectivity (albedo) of 0.7
    Insulation of Roof : U-value of 2.05
    Insulation of External Walls : U-value of 1.71
    Low-E Coated Glass : U-value of 1.8 W/m².K and SHGC of 0.28
    Energy-Saving Light Bulbs - Internal Spaces/Common Areas and External Spaces
    Lighting Controls for Common Areas and Outdoors
    Solar Photovoltaics - 0.84% of Total Energy Demand

    Second œuvre / Plomberie, sanitaire 

    Low-Flow Showerheads - 7.72 L/min
    Low-Flow Faucets for Kitchen Sinks - 8.05 L/min
    Low-Flow Faucets in All Bathrooms - 5.14 L/min
    Single Flush for Water Closets - 4.8 L/flush

    Second œuvre / Cloisons, isolation

    Internal Walls: Cellular Light Weight Concrete Blocks
    Flooring: Parquet/Wood Block Finishes/ Ceramic Tile

Construction and exploitation costs


Energy bill

  • 11 640,00

Water management

  • 5 505,60 m3
  • 45 kL/unit/year : shower
    32 kL/unit/year : kitchen
    17 kL/unit/year : water faucets
    20 kL/unit/year : water closets
    23 kL/unit/year : washing and cleaning

Comfort

    A green project is a project that can not be green or green, but must be green, to create an ecological environment with fresh air, thereby creating comfort, do Increase happiness index for residents and longevity of people.
    With the design of this green - sustainable - environmental friendly motto, EcoLife Capitol was built from nature-friendly materials in harmony with the landscape which do not pollute the environment and save maximum power sources. At EcoLife Capitol, work surfaces allow sunlight through subtly arranged spaces. Spaces and the architecture ratio are researched in terms of sun and wind direction to reduce the impact of climate and strong light. Rooftop greeneries provide oxygen and contribute to a comfortable living space.
    The residents of the EcoLife Capitol have seen the real value of the project in enhancing health indicators, good ecological environment, and significant energy savings

GHG emissions

  • 15,00 KgCO2/m2/year
  • CO₂ Emissions g/kWh of Electricity: 428.6 g/kWh

Reasons for participating in the competition(s)

​Energy (30% energy savings): Reduced window to wall ratio, reflective paint for external walls, insulation of roof and external walls, low-E coated glass, energy-saving lighting for external and internal spaces, lighting controls for common areas and outdoor spaces and solar photovoltaics.
Water (27% water savings): Low-flow plumbing fixtures for washbasins and kitchens and single flush water closets.
Materials (42% less embodied energy in materials): Cellular light weight concrete blocks for internal walls and parquet/wood block finishes for flooring.

Building candidate in the category

Energy & Hot Climates

Energy & Hot Climates

Users' Choice

Users' Choice

Green Solutions Awards 2019 - Buildings
PDF

Share :
Author of the page

EDGE Buildings


Other case studies

More

Contest