Passive House Drumderry
- by Zeno Winkens
- /
- 2019-06-17 18:26:11
- /
- International
- /
- 6536 / EN
New Construction
- Building Type : Isolated or semi-detached house
- Construction Year : 2016
- Delivery year : 2016
- Address 1 - street : Drumderry, Bunclody Y21 K8X3 CO. WEXFORD, Ireland
- Climate zone : [Cbc] Mild, dry winter, warm and wet summer.
- Net Floor Area : 227 m2
- Construction/refurbishment cost : 330 000 €
- Number of Dwelling : 1 Dwelling
- Cost/m2 : 1453.74 €/m2
-
Primary energy need :
40 kWhpe/m2.year
(Calculation method : Other )
The project brief was to design a CertifiedPassive House on a sloping site in Drumderry. The dwelling is approached frombelow. This family Bungalow achieved Passive House Certification and the Bungalow also has a Irish BER of A1 @ 6.73 kWh/ m2/ yr (Audited result).
This is a single storey family house located in the Irish countryside. The design is contributing minimal impact on the surrounding landscapes, taking advantage of natural daylight and optimising the free heat from the sun.
See more details about this project
https://www.winkens.ie/passivebc02.htmPhoto credit
Winkens Archiecture
Contractor
Construction Manager
Stakeholders
Environmental consultancy
Andrew Lundberg
Andrew Lundberg, [email protected]
Http:///www.passivate.iePassive House Designer
Contracting method
General Contractor
Type of market
Table 'c21_algeria.rex_market_type' doesn't exist
If you had to do it again?
The builder was not used to building low energy dwellings. He was a good builder and needed quite some tutoring. Some of this torturing should have been done earlier in the build.
Building users opinion
We wanted and got a Passive House. The design works well and comfort levels are high throughout the Year.
Energy consumption
- 40,00 kWhpe/m2.year
- 40,00 kWhpe/m2.year
Envelope performance
- 0,57
More information
With the PV installation, the house needs only 6.73 kWhpe /(m2a ).
Real final energy consumption
6,73 kWhfe/m2.year
Systems
- Geothermal heat pump
- Heat pump
- No cooling system
- compensated Air Handling Unit
- Solar photovoltaic
- Heat pump (geothermal)
Product
Heat pump
Unipipe.ie / Nibe
Unipipe
https://www.unipipe.ie/Génie climatique, électricité / Chauffage, eau chaude
Heating system:
Air to water heat pump NIBE F2040 used to underfloor heating distribution.
Hot water , direct electric water heater from PV panels with air to water heat pump contribution.
The stake holder were happy
Brink MHRV

BRINK
BRINK
https://www.brinkhrv.com/Génie climatique, électricité / Ventilation, rafraîchissement
Ventilation:
Brink Climate Systems B.V., Renovent Excellent 300 (Plus)
Heat recovery ventilation system supplying fresh air to all living rooms and extracting from all wet rooms. Effective efficiency of 84%
The stakeholder were happy.
External; Windows and Doors

True Windows
True Windows
http://www.truewindows.ie/Second œuvre / Menuiseries extérieures
Windows:
GUTMANN AG, MIRA therm 08, Timber frame with insulation and external aluminium shell
U w-value = 0.87 W/(m2K) Glazing Saint-Gobain glass, CLIMATOP LUX, Triple glazing 52 mm. Glass type 4(6)Gr- safety tempered glass. Warm edge spacer swisspacer. U g-value = 0.6 W/(m2K) g -value = 62 %
The stakeholder were happy.
PV Array

Solarelectric.ie
Paul Murphy
https://www.solarelectric.ie/Second œuvre / Equipements électriques (courants forts/faibles)
Electricity:
24.4 sq.m. of PV 15 panels installed on the roof with an annual electricity yield of the inverter of approx 3678 kWh/a
The stakeholders were happy
Insulation Floor

Hytherm
Hytherm
https://www.xtratherm.com/Gros œuvre / Système passif
Floor:
Strip foundation, concrete floor slab insulated with 300 mm rigid insulation EPS100. 65mm Sudanit 280 Fast Screed U-value = 0.107 W/(m2K)
The stakeholder were very happy with the products
Insulation Wall

Thermobead
Bunclody Insulations
Walls: Fully insulated cavity wall, with 250 mm expanded polystyrene (bonded bead) injected into cavity
U-value = 0.129 W/(m2K)
The stakeholder were happy.
Insulation Ceiling

Isover
Isover
https://www.isover.ie/
Roof:
Slated, timber roof trussed construction insulated with 420 mm Isover Heat shield, mineral wool insulation.
U-value = 0.084 W/(m2K) ceiling with suspended service cavity.
The stake holder were happy
Thermal Bridging

Passivate
Abdrew Lundberg
http://www.passivate.ie/Gros œuvre / Système passif
Thermal bridging:.
Mix of Irish ACDs, Quinn lite certified details and bespoke. First 2 course of Quinn Lite blocks, low thermal conductivity teplo cavity wall ties. Calculated Y-factor (W/m2K) 0.019
The stakeholders were happy.
Author of the page
Zeno Winkens
Architect
Other case studies

City Residential El Riyadh - Oran
- 19/11/2016
- /
- Omar MEZOUAR
- /
- 33386

Koranic El Djabiria Tafilelt Tajdit
- 03/07/2016
- /
- Ferial BOUNOUIOUA
- /
- 1214

Rural house - CNERIB
- 19/05/2016
- /
- Vincent Gilfaut
- /
- 14923

House Type Ksar Tafillelt
- 15/05/2016
- /
- abderrahmane zidane
- /
- 20894