Complesso Residenziale Solaria
Last modified by the author on 14/04/2014 - 09:12
New Construction
- Building Type : Collective housing < 50m
- Construction Year : 2011
- Delivery year : 2014
- Address 1 - street : Via San Carlo 15 70010 CAPURSO (BA), Italia
- Climate zone : [BSh] Subtropical Dry Semiarid (Steppe)
- Net Floor Area : 2 045 m2
- Construction/refurbishment cost : 1 300 €
- Number of Dwelling : 25 Dwelling
- Cost/m2 : 0.64 €/m2
Certifications :
-
Primary energy need
14 kWhpe/m2.anno
(Calculation method : Primary energy needs )
The building stands on a plot of a square corner in Via San Carlo Via Einaudi in Capurso (BA). The project is based on criteria such as innovation and building systems, sustainable materials and certificates with respect to health and the environment. They will also be subject to the provisions of the Regional Law n. 13 of 2008, which made him eligible to be recognized as a "pilot project" of a Memorandum of Understanding between the Puglia Region and the Municipality of Capurso, for the purpose of testing the Protocol Ithaca 2011 with the construction of apartments in the energy class A + and sustainability level 3. The building is spread over 4 floors used for residential and two car garage and basement used as cantinole, consists of 25 units divided into 6 different types of cutting and distribution covering an area of ââ2045.00 square meters, while the area devoted to parking is 2,420.00 square meters and the external relevance of the building is 1,280.00 square meters for parking places, garden area and access ramp to the basement. For the external areas has been provided the planting of native species.
Data reliability
Assessor
Stakeholders
Contractor
Gruppo Stolfa Edilizia s.a.s.
Via F.lli Cervi, 6 - 70010 Capurso (BA)
www.gruppostolfaedilizia.itConstruction company
Gruppo Stolfa Edilizia s.a.s.
geom. Antonio Stolfa
www.gruppostolfaedilizia.itThermal consultancy agency
Studio di ingegneria ing. Petrelli Francesco
Others
Consulente energetico-ambientale arch. Petrone Daniela
Contracting method
Build and sell construction
Owner approach of sustainability
Business ethics should be based on a new concept of the role of business today , combining the quality of life and economic development and profit , which translates into a Sustainable Development. My company is also committed to contributing to the dissemination of knowledge of the principles of sustainable building construction in accordance with Community rules, and being associated ANCE Bari -Bat and the District of Sustainable Puglia, as well as associated Confindustria, plays a role active in line with that of the associations, so that materializes a network of operators of excellence with the common interest to produce innovation for both the territory and for export of the same. If you do not tip on energy sustainability, it will be difficult to locate new housing on the market. Recent research confirms that the elements for the selection of new homes are rapidly evolving , until ten years ago it was thought to finish, today's safety and energy saving, in short, to reduce consumption.
Architectural description
The development does not seek formal aesthetic effects spectacular, but it translates into concrete forms of spaces well distributed. The extreme rigor and simplicity of the architectural composition, not to be confused with the schematic, define the volume of the building as a compact body, which aims to return to the readability scores. The design choices were influenced by feedback of bioclimatic nature, to enhance the contribution of solar and prevailing winds in the area. This will make a building with a low environmental impact.
If you had to do it again?
Assuming the absence of any repentance on innovative choices made, I would continue on the road to search for new engineering solutions and construction with the goal of consistently achieving houses to zero environmental impact.
Energy consumption
- 14,00 kWhpe/m2.anno
- 60,00 kWhpe/m2.anno
Envelope performance
- 0,18 W/m2K
- 0,57
Systems
- Heat pump
- Low temperature floor heating
- Solar thermal
- Heat pump
- Solar Thermal
- Reversible heat pump
- Floor cooling
- Natural ventilation
- Solar photovoltaic
- Solar Thermal
- 60,00 %
GHG emissions
- 3,16 KgCO2/m2/anno
- 100,00 anno/i
Water management
- 360,00 m3
- 360,00 m3
- 375,00 m3
Product
Climagold M / F 300 62,5 x20x42 cm; Climagold M / F 300 62,5 x25x15 cm
Xella Italia srl
-
http://www.ytong.it
Infill masonry exterior is of homogeneous type, built with blocks of aerated concrete with a thickness of 42 cm, transmittance of about 0,19 W/m²K - walls to the stairwell/dividers between different units: are of type cassette, with double lining of different thicknesses in cls autoclaved and interposing layer for thermal and acoustic insulation, consisting of a panel in polyester fiber coupled to a mattress made of crosslinked polyethylene closed cell foam, the transmittance of the wall thus obtained is approximately 0,20 W/m²K.
The product is a high performance in terms of breathability and thermal inertia.
Energy bill
- 120,00 €
Urban environment
The area on which the building stands is located south-west of the city within walking distance from the center, the area is completely urbanized, in the vicinity of a line of local public transport and is fully served by sewerage, mains electricity, mains drinking water, methane gas network.
Land plot area
1 300,00 m2
Built-up area
60,00 %
Green space
100,00
Parking spaces
NR. 18 parking spaces on the ground floor
Building Environmental Quality
- Building flexibility
- indoor air quality and health
- acoustics
- comfort (visual, olfactive, thermal)
- water management
- energy efficiency
- renewable energies
- mobility