Passive House Farhaus AF1

5554
Last modified by the author on 19/02/2013 - 10:14

New Construction

  • Building Type : Isolated or semi-detached house
  • Construction Year : 2012
  • Delivery year : 2012
  • Address 1 - street : c/Moià 168 08183 CASTELLTERçOL, Spain
  • Climate zone :

  • Net Floor Area : 125 m2
  • Construction/refurbishment cost : 150 000 €
  • Number of Dwelling : 1 Dwelling
  • Cost/m2 : 1200 €/m2

Certifications :

  • Primary energy need
    107 kWhpe/m2.year
    (Calculation method : Primary energy needs )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building
Detached family house in Castellterçol, a village 45kms in the north of Barcelona. The house has been built following the “Passivhaus standard”, and is actually is certification process (02/2013). The heating demand is 13kwh/m2&year (with PHPP) which is 6 times less than the actual Spanish energy standard (CTE).The summer confort is reached without air conditioning. The overheating frecuency (reference 25ºC) meets the confort criteria established by international norm ISO-EN-7730.

See more details about this project

 http://www.energiehaus.es/index.php/consultoria/consultoria-estandar-passivhaus/ejemplos-passivhaus

Stakeholders


Contracting method

Other methods

If you had to do it again?

Begin the energy development from the first planification.

Building users opinion

The users are very happy and comfortable with the building.
The building is actually being monitorised to compare with PHPP results.

Energy consumption

  • 107,00 kWhpe/m2.year
  • 264,00 kWhpe/m2.year
  • Primary energy needs

    Heating: 7,7kWh/m2a
    Sanitary water: 17,3kWh/m2a
    Appliances: 12,6kWh/m2a
    Auxiliar energy (ventilation included): 3,8kWh/m2a

Envelope performance

  • 0,13 W.m-2.K-1
  • All materials of the thermal envelope (exept foundations) are from vegetal or reused materials such as wood or paper.

  • 0,31
  • n50

  • 0,61

More information

Building actually in monitoring phase.

Real final energy consumption

    41,00 kWhfe/m2.year

Systems

    • Heat pump
    • Heat pump
    • No cooling system
    • Double flow heat exchanger
    • No renewable energy systems

Energy bill

  • 1 300,00

Life Cycle Analysis

    All materials used are from vegetal or reused materials such as wood or paper.
    Strong timber frame spruce structure.

Indoor Air quality

    The CO2 concentration is actually measured with a Wöhler-CO2 data logger.
    The CO2 level does not exceed 1000ppm.

GHG emissions

  • 28,10 KgCO2/m2/year
  • PHPP - Passive House Design Package

PDF