Zehnder Campus

16017
Last modified by the author on 17/06/2015 - 18:44

New Construction

  • Building Type : Office building < 28m
  • Construction Year : 2014
  • Delivery year : 2015
  • Address 1 - street : 3, Rue du Bois Briard 91021 COURCOURONNES, France
  • Climate zone : [Cfb] Marine Mild Winter, warm summer, no dry season.

  • Net Floor Area : 3 500 m2
  • Construction/refurbishment cost : 8 500 000 €
  • Number of Work station : 160 Work station
  • Cost/m2 : 2428.57 €/m2

Certifications :

  • Primary energy need
    25 kWhep/m2.an
    (Calculation method : RT 2012 )
Energy consumption
Economical buildingBuilding
< 50A
A
51 à 90B
B
91 à 150C
C
151 à 230D
D
231 à 330E
E
331 à 450F
F
> 450G
G
Energy-intensive building

Building three functions: Offices, Showroom and Training Center. French headquarters of Zehnder Group.

Triple Certified Building:

  • MINERGIE P
  • LEED Silver
  • BREEAM Very Good

Sustainable development approach of the project owner

The objectives of Zehnder Group through this building are:
- The quality of indoor environments and comfort of workingspaces for employees (it is the headquarters of Zehnder Group in France)
- The construction of a training center for products testing and training of customers and partners
- The implementation and demonstration of Zehnder Group solutions performance on energy efficiency and indoor comfort
- Building certifications (international label)

Architectural description

This building is triple function:
- 2400 m2 of offices and social rooms, partly ERP
- 300 m2 of exhibition space
- 800 m2 dedicated to the training center. For more detail, please refer to plans and photos.

Building users opinion

Too soon for a return - from the occupation 29/06/2015

Stakeholders




Contracting method

General Contractor

Type of market

Realization

Energy consumption

  • 25,00 kWhep/m2.an
  • 50,00 kWhep/m2.an
  • RT 2012

Envelope performance

  • 0,20 W.m-2.K-1
  • EN 13829 - n50 » (en 1/h-1)

  • 0,46

Systems

    • Geothermal heat pump
    • Radiant ceiling
    • Individual electric boiler
    • Geothermal heat pump
    • Radiant ceiling
    • Double flow heat exchanger
    • Heat pump (geothermal)

Smart Building

    GTB Delta Dore - Web Interface

    too early

Urban environment

  • 10 000,00 m2
  • 1 300,00 %
  • 5 000,00
  • Downtown Courcouronnes, near tramway (300 m) and bus (foot)

Product

    Radiant panel heating and cooled ceilings ceiling systems

    Zehnder

    Zehnder Group France

     http://www.zehnder.fr

    HVAC, électricité / heating, hot water

    see manufacturer documentation

    Aesthetic and energy efficiency, heating + refresh Comfort of radiant heating and cooling: no air mixing and convection


    Ventilation central piece dual flow heat recovery

    Zehnder

    Zehnder Group France

     http://www.zehnder.fr

    HVAC, électricité / ventilation, cooling

    See manufacturer instructions

    Energetic Efficiency


    Air distribution ducts integrated slab - ComfoTube

    Zehnder

    ZEHNDER GROUP FRANCE

     http://www.zehnder.fr

    HVAC, électricité / ventilation, cooling

    view manufacturer website

    Space saving: integration slab. Hygiene: distribution ducts with patented principle of "double-skiN"; for easy maintenance and limiting the deposition of dust.

Construction and exploitation costs

  • 8 500 000

Indoor Air quality

    IAQ measurements made at the end of construction phase, before occupation and renewed after occupation. Results not yet available. Collaboration Médiéco - Suzanne DEOUX very early in the design phase and during the construction phase to validate the components used.

Comfort

    Regarding comfort, our ambition is to create a comfortable indoor amabiance for our employees and visitors. The principles key are: - Radiant heating, soft and uniform heat, immediately perceptible in all areas - Totally silent operation in summer and winter - no uplift displacement and dust in space. no perceptible air movement by the occupants - The air filtered by a double flow ventilation is blown at room temperature - Management of different components by an intelligent BMS concerning health. Our ambition is to contribute to a perfect in-door quality for the health of occupants. We focus on the quality of air circulation, ambient temperature, decrease odor, dust, pollen and parasites, the humidity and sound level - Daylight brought by exposure of the building and the glass partition to use in interior design - sunscreens - landscaping, choose plants and non-allergenic esssences tratement internal acoustic - Heating and raffraîchissment - internal materials selection - Custom IAQ
    We brought along throughout the project, from the design by the Cabinet MEDIECO Suzanne DEOUX, recognized expert in IAQ.

    Simulation thermique dynamique faite - voir notice energie - logiciel Virtual Environment v 6.4.0.5

Reasons for participating in the competition(s)

​L'objectif de Zehnder group en construisant ce bâtiment est la réalisation d'un bâtiment exemplaire qui intègre ses savoir-faire pour créer des solutions d'ambiances intérieures confortables, saines et économes en énergie.

Zehnder Group a ainsi utilisé toute la palette de ses savoir-faire et solutions en matière de chauffage, ventilation, rafraîchissement et traitement de l'air, et s'est entouré d'experts reconnus tels que S. DEOUX ( Médiéco) dans le domaine de la Qualité d'air intérieur.

Le confort des collaborateurs Zehnder Group France SAS a été au centre de la conception du bâtiment.

L'architecture du batiment privilégie la lumière naturelle. La triple labelisation Minergie / breeam / LEED est venue naturellement appuyer la demarche.

Building candidate in the category

Health & Comfort

Health & Comfort

Green Building Solutions Awards 2015
PDF

Share :
Author of the page

Pierre DUCLUSAUD

DG Zehnder Group France - Finance et fonctions support


Other case studies

More

Contest